19
EEWB332B
4.5.4 Manual Parameter Entry
In the event of automatic gauge failure, the param-
eter values can be input manually. See manual
entry of rim width in the previous paragraph.
D
W
O
Figure 24a
Figure 24b
Figure 24c
4.5.4.1
Manual Rim Diameter Entry
- Select the
Manual Diameter button. Read the rim diameter
marked on the sidewall of the tire (Figure 24a and
24b). Press the Diameter Button (D) and enter the
measured rim diameter by selecting the +/- keys
until the desired value appears in the display.
4.5.4.2 Manual Distance Entry
- Move the distance
gauge arm to touch the inner edge of the wheel
where weights are to be placed and observe the
reading on the scale of the distance gauge. See
Figure 24c. Press manual Wheel
Offset
button
(O) followed by selecting the +/- keys until value
is displayed in the display window.
NOTE:
The parameter arm must be in the Home
rest position when the balancer is powered up.
This establishes the arm starting position.
Figure 25
4.6
Easy Alu FUNCTION
The
Easy Alu
function automatically recognizes the
desired weight location by placing the SAPE arm in
the correct locations.
Note
:
Alu 4 and Alu 5 are not included in the
Easy Alu
function. They require manual setting by the operator.
4.6.1
Automatic rim dimension reading
and setting and Alu Mode
Preparations:
—
Compensation run carried out, if necessary.
—
Wheel correctly clamped.
Important:
The OK indication and recommendation
for optimization, as well as the optimization procedure
itself, will only be accurate if the rim width is correctly
entered (Sonic sensor or Manual Input).
Automatic rim distance and diameter reading with
an internal gauge arm
—
Move the internal gauge arm into position on the
rim to select the initial weight application position
(internal rim side). Keep it in this position until an
audible signal is heard.
Only for Alu2P and Alu3P
(
Fig. 25
):
—
Position and hold the internal gauge in the
second position on the rim to select the
application position on the right side of the rim.
Shortly afterwards the machine emits an audible
signal to indicate that the machine automatically
saves the weight application coordinates.
—
Move the gauge to the idle position.
—
For Alu2P and Alu3P you can start the spin.
—
For all the other Alu, previously enter the rim Width.
At this point you can change the Alu mode suggested
by the machine, using the “
Easy Alu Toggle
” function.
Do this by pressing the key
once.