16
EEWB330B
4.4 SELECTING OPERATOR PREFERENCES
4.4.1 FINE BALANCING MODE
This balancer measures with the maximum precision
availa ble all the time, 1g / 0.05 oz, however values
below 5g / 0.25 oz are shown as zero while in the nor-
mal operating mode. Values exceeding 5g / 0.25 oz
are rounded to the amount of the nearest commercial
wheel weight.
Press the
FINE
button to advance to the display resolu-
tion between 5g / 0.25 oz and 1g / 0.05 oz.
4.4.2 OUNCE/GRAMS CONVERSION
When the machine is fi rst turned on it is preset to display
the imbalance in ounces.
Press the
MODE
button to advance to select ounces
or grams.
Select Enter to save selection.
4.4.3 RIM DIAMETER IN MILLIMETERS
The rim diameter is normally displayed in inches,
however if the value in millimeters is desired. Press
the MODE button until “PAX/mm” is NOT illuminated
to display in inches, when lit the unit displays in mm.
4.5 ENTER RIM PARAMETERS
4.5.1 Rim Distance (offset)
- Move the rim offset
arm to the edge of the rim, touch the pointer to the
rim edge as illustrated in Figure 19 and hold steady
for about a second. The beeper will sound when the
distance and diameter values are calculated and en-
tered. Return the arm to its fully in and down position
on the balancer. Do not allow the measurement arm to
“dangle” down in front of the balancer
.
W
Figure 21
Figure 19
Figure 20
4.5.2. Measure/Enter rim width
using rim width
caliper. Measure wheel where corrective clip-on weight
would be applied, Figure 20.
Press the Width entry key, Figure 21-W, and enter the
measured width by pr/- keys until the desired
value appears in the display.
Select Enter to save selection.
Содержание EEWB330B
Страница 1: ...EEWB330B DIGITAL WHEEL BALANCER OPERATOR S MANUAL MANUEL OPÉRATEUR MANUAL DE OPERADOR ...
Страница 2: ......
Страница 38: ...38 EEWB330B NOTES ...
Страница 74: ...74 EEWB330B REMARQUES ...
Страница 110: ...110 EEWB330B NOTAS ...
Страница 111: ...111 EEWB330B NOTES ...