Snap
‐
on
EEW
B
33
0
A
Handspin
Wheel
Balancer
Code
C7
Volume
of
audible
signal
Scale
of
volume
0
to
100
(low
–
high),
Normally
set
to
50*
Example:
Adjusting
the
volume
to
60.
Select
Code
C7.
Set
the
desired
value.
Press
ENTER
Note:
The
selection
is
permanently
acquired.
Code
C8
Selecting
the
limit
(threshold)
value
for
suppression
of
minor
unbalance
readings
in
grams,
or
ounces.
The
unit
of
measurement
(grams
or
oz)
depends
on
the
setting.
5.4.3).Grams:
Range
3.50
to
20.0
grams.
Factory
‐
adjusted
to
5.0*
grams.
Select
another
limit,
e.
g.:
5.50
grams.
Select
Code
C8.
Set
the
value
5.50.
Press
ENTER.
Ounces:
Range
0.12
to
0.71
oz
Factory
‐
adjusted
to
0.18*
oz.
Select
another
limit,
e.
g.:
0.50
oz
Select
Code
C8.
Set
the
value
0.50.
Press
ENTER
Note:
The
selection
is
permanently
acquired.
*
=
Factory
adjusted
mode