DATASHEET
8.4.1.2
EEPROM Configuration Timing
Figure 8.4 - Timing to Complete Configuration from EEPROM
Table 8.8 - Time Values to Configure From EEPROM
NAME DESCRIPTION
MIN
TYP
MAX
UNITS
T1 RESET_N
asserted
100
nsec
T2 (I
2
C) USB20H04 recovery/stabilization – until
first rising edge of SCK/SCL
24
30
μ
sec
T3 (I
2
C) EEPROM configuration to final
SCK/SCL activity
8
10
msec
T4
Configuration finished to Hub enabled
35
70
nsec
RESET_N
t1
t2
t3
GND
Hardware
Reset Asserted
CS/EE_SEL
& SMB_SEL_N
strapping
options read
First Clock
Rising Edge
Configuration
Finished
SCK/SCL
t4
Hub Function
Enable