![Smooth-Air HEX390 digi Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/smooth-air/hex390-digi/hex390-digi_operating-instructions-manual_1306649010.webp)
HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015
10
Press together 5 secs to get
Setup Menu
,
display will then change to:
1. Heater Kit
Y/N
(default N).
If N - heater options are removed from all menus.
If Y - heater options are available in User menu - Heater On/Off for
continuous or night heat (to times as set below) .
To set night heat option:
• press up arrow to select
Y
, then:
• press mode to display ‘
Heater Times
’
>display then changes
automatically to show the current settings (default: )
>display changes again to ‘
Change Times
’
Y/N (default N).
• At this point, use then to select
Y
& change the times.
• Select desired
Heater ON
time in Hours:Mins using or
• Select desired
Heater OFF
time in Hours:Mins using or
•
Heater Test
Y/N (default N)
• change to Y, heater test will be performed. If there are any faults
(including no heater connected), ‘
Heater Fault
’
will display. (See
menu item
4.Fan Speed Heat
for possible Heater Fault causes.)
To reset Heater Fault display, turn unit off.
2. Max Fan Speed
(default 100%) – Range is 10% to 100% adjustable in
10% increments using up & down arrows.
For a large house set to a max of 100%.
3. Min Fan Speed
(default 10%) – Range is 10% to 100% adjustable in
10% increments using up & down arrows.
For a large house set to a min of 50%
4. Fan Speed Heat
(default 50%) – Range is 10% to 100% adjustable in
10% increments using up & down arrows.
Fan Speed Heat
sets a minimum speed for the fan to ensure
enough airflow for the heater to operate. There are many duct fan
combinations, some more restrictive to airflow than others. Therefore,
when setting up, the installer must check that the heater operates
without ‘
Heater Fault
’ flashing on the display. ‘Heater Fault’ is triggered
when the heater is operating but draws no current, this is most often
due to insufficient airflow causing the airflow proving switch to cut off.
If there is insufficient airflow, increase the ‘Fan Speed Heat’ setting.
Heater fault may also be caused by manual reset thermal cutouts which
may need to be reset.
Heater ON 19:00
Heater OFF07:00
Heater option not available for HEXdigi-NH
Heater option not available for HEXdigi-NH
Use up arrow to change, then
mode to advance through menu
Use Mode button to scroll
through options
Press up and down arrows
together for 5 secs to get to
Setup Menu