SMOKE-FACTORY –
DATA II
Operating Instructions
5.3.4 Operating cable remote and 0-10V (+) DC
Connect the
DATA II
to an analog desk or to the cable remote (available as an optional extra), use the
3pin XLR socket at the back of the machine.
Please note
: With analog control the pump can be adjusted from the desk and/ or the cable remote.
The fan has to be adjusted directly at the machine.
•
Connect the cable from the desk or the cable remote into the XLR socket at
the back of the machine.
•
The knob on the cable remote or the fader on the analog desk will control the
level of the pump.
•
Pressing the On/Off switch at the cable remote starts the fog process.
To adjust the fan output press the Mode-button until a „F“ and two figures appear on the
display.
•
Adjust the fan output with the Up/Down-buttons .
5.3.5 Control via Radio remote
A radio remote is available as an option. It will be delivered with a 3pin XLR plug. Connect the receiver
of the radio remote to the machine by using the 3pin XLR socket on the back of the machine.
Adjust the requested pump output at the machine (see point 6.3.3). Press the first button at the
transmitter of the radio remote as long as you want fog to be produced (see manual „Radio remote“).
XLR 3pol connector
radio reciver
Start button fogging
process tranmitter.
5.3.6 Wiring of DMX und Analog 0-10V DC
DMX:
Pin 1 = Ground (Masse), Pin 2 = DMX-, Pin 3 = DMX+, Pin 4 und 5 = nc
3pol-XLR (analog):
Pin 1 = Ground (Masse), Pin 2 = 0-10 V + DC in, Pin 3 = 12 V + DC out, max. 50mA
SMOKE FACTORY
issue 1.0 Page: 10 of. 15
FOG GENERATORS NEBELMASCHINEN