Smitson JM-LED01 Скачать руководство пользователя страница 5

4

φ

360

φ240

φ1

20

8-

φ

14

  

material:  GB700: Q235
           ASTM : A283GRC  A306GR55
           JIS  : G3113-87  SAPH38

φ300

φ

360

φ1

20

φ300

thickness: 8m m
sup erficial treatm ent:antirust lacq uer

thickness: 12m m
sup erficial treatm ent:antirust lacq uer

p icture 4: p ressure p late

p icture 5: m o unting  d isk

All fasteners of the installed components must be reliable and fastening to prevent

the harm due to loose. when mounting, the bottom of mounting base must be adjusted

to level condition, otherwise it would cause the drift of lamp.

Ground wire(color: yellow or green) must be grounded reliably, in order to ensure the

use of safety.

With installed problems, please contact with the manufacturer before construction.

Mounted steps

1. according to picture 1 and picture 2 in the operation instruction, drill four Ф16mm

holes on the floor plate with impact drill in determined place. pressure plate and

mounting disk must be tightened with screw M12 in the appropriate length, according

to picture 3.

2. According to mounted diagram, connect the rotating arm to the mounting plate,

regulate it to horizontal place, and tighten it according to picture 3.

3. Connect two balance arms to rotating arms respectively, and connect the

conductive plug. then tighten the two parts with the distributive screw.

4. According to the instruction for the balance arm of Ondal, link the conductive plug,

connect two lamps to the balance arms respectively, and make sure that it is reliable.

5. After careful examination and confirmation, debug the equipment with energizing

according to the operation instruction.

www.smitsonjupiter.com

Содержание JM-LED01

Страница 1: ...LED Shadowless Lamp JM LED01 USER MANUAL Smitson Jupiter Ltd Gillingham United Kingdom www smitsonjupiter com info smitsonjupiter com ...

Страница 2: ...ly voltage AC220 10 V Frequency 50Hz Input power 70VA Main lamp power 70W 2 3 suitable mounting height 3200 3300 mm Low storey may bring inconvenience to users please refer to the product diagram in special circumstances you should contact with the manufacturer when purchasing 3 Technical specifications Type JM LED01 Main lamp Diameter of Light Head mm 500 Quantity of LEDS 48 Illumination 10 Steps...

Страница 3: ...l dr i ve cont r ol m ai n l am p assi st ant l am p useri nt er f ace useri nt er f ace 5 Installation The equipment is fixedly mounted on the roof The floor must bear the weight of the device but also bear the force moment because of partial load and the operation In order to ensure the safety the floor should have enough bearing capacity and strength Users can make construction according to the...

Страница 4: ... ur e 1 t he r oofw i t h decor at i ve l ayer pr essur e pl at e fl oorpl at e on t he r oof m ount i ng di sk m ount i ng base pi ct ur e 2 t he r oofw i t houtdecor at i ve l ayer m ounti ng di sk m ounti ng base screw M 12 nut M 12 spri ng w asher 12 fl at w asher 12 pressure pl ate pi cture 3 enl arged vi ew of screw assem bl y www smitsonjupiter com ...

Страница 5: ...ion Mounted steps 1 according to picture 1 and picture 2 in the operation instruction drill four Ф16mm holes on the floor plate with impact drill in determined place pressure plate and mounting disk must be tightened with screw M12 in the appropriate length according to picture 3 2 According to mounted diagram connect the rotating arm to the mounting plate regulate it to horizontal place and tight...

Страница 6: ...ton increasing brightness the illumination will rise a gear When up to the maximum 10 gear the maximum illumination symbols will lights each time you press the button weakening brightness the illumination will decline a gear up to the lowest illumination The electronic control system of the equipment has memory function So it can adjust to the last used gear illumination when rebooting Spot adjust...

Страница 7: ...put the handle in high pressure steam sterilizer in order to avoid deforming It can use peroxyacetic acid solution glutaruc dialdehyde solution and medical alcohol to disinfect in normal temperature 7 Maintain Damping adjustable rotating arm The center seat of 2 rotating arms has 2 damping adjustment screws If it drifts after using for some time you can tighten the damp with wrench according to pi...

Страница 8: ...cut off power supply of shadowless operating lamps rise the lamp head to the highest place to be convenient to clean the operating room and to avoid that the cleaning equipments collide the shadowless operating lamps C Non professionals do not dismount the device at option In addition to the LED module inside the device there is no device what users can replace 8 Warranty The warranty period of ou...

Страница 9: ...gulations Metallic article may become renewable resources and e waste should be treated with harmless 10 Packing List 1 Rotating arm 1 2 Balance arm Ondal 1 3 Main lamp 1 4 Handle 4 5 Product certificate 1 6 Manual 1 7 Warranty sheet 1 8 Instruction for balance arm Ondal 1 9 Inner hexagon spanner L M S 1 10 Fuse F2AL250V 4 Smitson Jupiter Ltd Gillingham United Kingdom www smitsonjupiter com info s...