CABLE ENTRY
PIPE ENTRY
HINGED GRILLE
VALVE ACCESS PANEL
FILTER RETAINER
Introduction
This heater is designed to be installed into suspended T-bar and plasterboard ceilings (The
minimum height of the void into which the unit will be installed should be a minimum of 250mm).
User Information:
This heater must not be installed in wet rooms or other high humidity areas.
This heater is designed for use on standard two-pipe pumped central heating systems with a
maximum water temperature of 86° C and a maximum pressure of 6 bar (88lbs/in²).
Pipe connections are 22mm and either pipe may be used as flow or return.
This heater is classified as a fixed appliance and the electrical connection should be via a 3A fused
spur. The fused spur must
not
be directly below the heater but should be accessible after
completion of the installation. This heater must be earthed.
It is recommended that this heater is wired via a remote room thermostat.
To avoid the possibility of vibration this heater must be fitted to a flat even surface.
This heater is fitted with a 35°C Low Limit Stat (L.T.C).
To conform to Building Regulations Part L (Part J in Scotland), a remote room thermostat can be
used in conjunction with this heater. Refer to the instructions supplied with the thermostat.
Please note the guarantee may be invalidated if this product is not installed and used in
accordance with these instructions.
For further details please contact our Technical Support on 01245 324560.
Figure 1
2
Fault Finding
1)
The fan does not run on any switch setting.
a)
Check the power supply is switched ON.
b)
Check the fuse in the fused spur.
c)
Check the wiring at the fused spur.
2)
No heat output.
a)
Vent any trapped air from the system (with the heating system turned OFF).
b)
Check the central heating is switched ON.
c)
If a thermostat is fitted ensure it is calling for heat.
d)
Balance the central heating system if installed on the same circuit as panel radiators and
increase the circulating pump speed if required.
e)
Increase the boiler water temperature.
In the event of difficulty please contact our technical help-line on 01245 324560. It will be helpful if
you do not disconnect the heater from the central heating system.
Information and advice
A product brochure containing full technical specifications and list prices is available to
download from our website or in hard copy from our office. Also available on our website are
price lists, individual product datasheets, installation & user guides, where to buy, who to
contact and a media centre.
Alternatively contact our office 9.00am to 5.00pm Monday to Thursday, 9.00am to 4.00pm on
Friday.
7
Optional Accessories
Optional accessories are available to offer additional control or functionally not offered by the heater
in its standard configuration.
Electrical Accessories
External Control Harness EXTCH
Allows for the standard unit controller to be relocated externally from the heater.
Adjustable low temperature cut-out UVCALTC T3
This enables the end user to precisely select the temperature at which the fans will switch on when
combined with different heat sources.
Miscellaneous Accessories
Caspian 22mm Flexible Hoses CAS22FH
Replacement air filters.
For accessories or spares please contact either your supplier or Smith’s Environmental
Products Ltd.