User information: 
 

Cleaning and user maintenance shall not be made by children without 
supervision 

 
Children of less than 3 years should be kept away unless continuously 

supervised 
 
Children aged from 3 years and less than 8 years shall only switch on/off 

the appliance provided that it has been placed or installed in its intended 
normal operating position and they have been given supervision or 

instruction concerning use of the appliance in a safe way and understand 
the hazards involved. Children aged from 3 years and less than 8 years shall 
not plug in, regulate and clean the appliance or perform user maintenance. 

 
CAUTION — Some parts of this product can become very hot and cause 

burns. Particular attention has to be given where children and vulnerable 
people are present

 

 

NOTES 

 

 

………………………………………………………………………………………………….. 

 

 

 

………………………………………………………………………………………………….. 

 
 

………………………………………………………………………………………………….. 

 
 

………………………………………………………………………………………………….. 

 

 

 

………………………………………………………………………………………………….. 

 
 

………………………………………………………………………………………………….. 

 
 

………………………………………………………………………………………………….. 

 

 

 

………………………………………………………………………………………………….. 

 
 

………………………………………………………………………………………………….. 

 
 

………………………………………………………………………………………………….. 

 

 

 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 

 

 

Fault Finding 

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 
 
 

 
 

 
 

 
 

 
 

 

 

 

 

1. Fan does not run on any switch setting or no 

heat output on electric heating mode. 

a. Check the power supply is switched ON. 

 
b. Check the fuse in the fused spur. 

 
c. Check the wiring connections at the fused 

spur. 
 

2. No heat output on hydronic heating mode. 

a. Check the power supply is switched ON. 
 

b. If fitted, ensure the room thermostat is calling 
for heat. 

 

c. Balance the central heating system if installed 
on the same circuit as panel radiators and 

increase the circulating pump speed if required. 
 

d. Increase the boiler water temperature. 
 

3. If the overheat protection has activated on 
electric heating mode, manually reset as follows. 

a. Switch the power supply OFF at the fused 
spur. 

 
b. Wait five minutes for the overheat cut off 

switch to reset and then switch the power supply 
ON. 

 

In the event of any difficulty, please contact us on 01245 324560. 

It will be more helpful if you do remove the product from the central heating system. 

 

Heat Output Performance 

 

It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat 
loss at normal heat output (l) enabling the boost setting (ll) to be used for faster heat up. 

 

 

Heat Output at 80°C 

Heat Output at 70°C 

Heat Output at 60°C 

Heat Output at 50°C 

Heat Output at 40°C 

 

Model 

 

Normal 

KW 

(BTU) 

Boost 

KW 

(BTU) 

Normal 

KW 

(BTU) 

Boost 

KW 

(BTU) 

Normal 

KW 

(BTU) 

Boost 

KW 

(BTU) 

Normal 

KW 

(BTU) 

Boost 

KW 

(BTU) 

Normal 

KW 

(BTU) 

Boost 

KW 

(BTU) 

SS5/Dual 

1.3 

(4400) 

1.7 

(5800) 

1.1 

(3800) 

1.4 

(4700) 

0.9 

(3100) 

1.1 

(3800) 

0.7 

(2400) 

0.9 

(3100) 

0.5 

(1700) 

0.7 

(2400) 

Notes:  

Dual models include an electric element which in electric heating mode will emit 1kW of heat. 
 

Heat outputs tested in accordance with BS 4856 using entering water temperature. Fan-only option operational only 
when central heating system is switched off.  

 

Heat output data for all water temperatures between 80°C and 40°C is available on our website 

www.smiths-env.com. Refer to the data sheet in the download section.

 