10
INSTALLATION CONSIDERATIONS
MODEL
DIMENSIONS
HEIGHT
WIDTH
DEPTH
INCHES (CM)
INCHES (CM)
INCHES (CM)
XWH 150
33-1/4" (84.5)
15-1/2" (39.4)
18" (45.72)
XWH 200
33-1/4" (84.5)
15-1/2" (39.4)
22-1/4" (56.5)
XWH 285
42-1/2" (107.95)
15-1/2" (39.4)
19-3/4" (50.2)
XWH 400
42-1/2" (107.95)
15-1/2" (39.4)
27" (68.6)
XWH 500
42-1/2" (107.95)
15-1/2" (39.4)
31-1/4" (79.4)
XWH 600
42-1/2" (107.95)
15-1/2" (39.4)
36-1/4" (92.1)
XWH 700
42-1/2" (107.95)
15-1/2" (39.4)
40-1/4" (102.2)
XWH 800
42-1/2" (107.95)
15-1/2" (39.4)
42-1/4" (107.3)
GAS LINE CONNECTION SIZE
TABLE 2
† MODEL
SERIES NATURAL GAS
NPT
PROPANE GAS
NPT
XWH 150
100
1/2”
1/2”
XWH 200
100
1/2”
1/2”
XWH 285
100
3/4"
3/4"
XWH 400
100
1"
1"
XWH 500
100
1"
1"
XWH 600
100
1"
1"
XWH 700
100
1"
1"
XWH 800
100
1"
1"
† Depending on the installed equivalent length, and/or the number of appliances connected,
the supply gas line size may have to be increased beyond the minimum required sizes - see
Table 23 on Page 44.
STORAGE CAPACITIES
TABLE 3
MODEL
U. S. GALLONS
LITERS
XWH 150
1.3
4.9
XWH 200
1.7
6.4
XWH 285
2.4
9.1
XWH 400
3.4
12.9
XWH 500
4.2
15.9
XWH 600
4.2
15.9
XWH 700
5.0
18.9
XWH 800
5.7
21.6
GAS PRESSURE REQUIREMENTS
TABLE 4
MODEL
*MANIFOLD PRESSURE
MINIMUM SUPPLY PRESSURE
MAXIMUM SUPPLY PRESSURE
NATURAL GAS
PROPANE GAS
NATURAL GAS
PROPANE GAS
NATURAL GAS
PROPANE GAS
XWH 150
-0.22” W.C. (-0.054 kPa) -0.23” W.C. (-0.057 kPa) 4” W. C. (1 kPa)
8” W. C. (2 kPa)
14” W. C. (3.49 kPa) 14” W. C. (3.49 kPa)
XWH 200
-0.39” W.C. (-0.09 kPa)
-0.39” W.C. (-0.09 kPa)
4” W. C. (1 kPa)
8” W. C. (2 kPa)
14” W. C. (3.49 kPa) 14” W. C. (3.49 kPa)
XWH 285 -0.68” W.C. (-0.17 kPa)
-0.71” W.C. (-0.18 kPa)
4” W. C. (1 kPa)
8” W. C. (2 kPa)
14” W. C. (3.49 kPa 14” W. C. (3.49 kPa)
XWH 400
-1.45” W.C. (-0.36 kPa)
-1.40” W.C. (-0.35 kPa)
4” W. C. (1 kPa)
8” W. C. (2 kPa)
14” W. C. (3.49 kPa) 14” W. C. (3.49 kPa)
XWH 500
-0.20” W.C. (-0.05 kPa)
-0.20” W.C. (-0.05 kPa)
4” W. C. (1 kPa)
8” W. C. (2 kPa)
14” W. C. (3.49 kPa) 14” W. C. (3.49 kPa)
XWH 600
-2.17” W.C. (-0.54 kPa)
-2.72” W.C. (-0.67 kPa)
4” W. C. (1 kPa)
8” W. C. (2 kPa)
14” W. C. (3.49 kPa) 14” W. C. (3.49 kPa)
XWH 700
-2.97” W.C. (-0.74 kPa)
-3.58” W.C. (-0.89 kPa)
4” W. C. (1 kPa)
8” W. C. (2 kPa)
14” W. C. (3.49 kPa 14” W. C. (3.49 kPa)
XWH 800 -3.50” W.C. (-0.88 kPa)
-4.30” W.C. (-1.1 kPa)
4” W. C. (1 kPa)
8” W. C. (2 kPa)
14” W. C. (3.49 kPa) 14” W. C. (3.49 kPa)
* The manifold pressure is the factory setting and is not adjustable. A negative pressure will be seen with just the blower running without the Gas Control Valve open.
ELECTRICAL REQUIREMENTS
TABLE 5
Model
Voltage/ Heater Voltage/ Pump Voltage/ Control Total AMPS W/ Pump # Of Electrical Connections
XWH 150
120
120
24
3.0
1
XWH 200
120
120
24
3.2
1
XWH 285
120
120
24
4.5
1
XWH 400
120
120
24
6.5
1
XWH 500
120
120
24
5.7
1
XWH 600
120
120
24
5.7
1
XWH 700
120
120
24
12.8
1
XWH 800
120
120
24
12.8
1
ROUGH IN DIMENSIONS
TABLE 1