Smith-Root APEX BACKPACK Скачать руководство пользователя страница 10

10

USER’S GUIDE

2021

BATTERY COMPARTMENT

Opening the battery compartment allows 

the user to install or change the battery, or 

connect the anode, cathode, and control 

circuit connectors (Figure 8). Remove the 

battery compartment cover by flipping 

the handles on the three cam-lock latches 

out and turning them counterclockwise. 

Make sure the latch on the bottom of the 

cover is free, then pull out on the two side 

latches and lift the battery compartment 

cover away from the Apex.
When replacing the battery compartment 

cover, adjust it so that it is on the inside of 

the molded guides of the pack frame. The 

cover must be correctly placed before the 

Apex will operate.
Close the cover latches.

BATTERY CONNECTOR

The battery connector, located inside the 

battery compartment, is a rectangular red 

and black plastic connector on the end of 

the input power cable (Figure 9). It mates 

with an identical connector on the Apex 

battery packs.  This connector is color 

coded and polarized to prevent accidental 

reverse connections of the battery.  

ANODE AND CATHODE CONNECTORS

The anode and cathode connectors are 

black plastic circular 2-pin connectors 

located on the bulkhead between the 

battery compartment and the electronics 

compartment (Figure 10). Access to 

these connectors is gained by removing 

the battery compartment cover.  The 

connectors are identical and allow the use 

of a trailing cathode cable or a cathode 

pole for greater control over placement 

of the output electric field.  Both pins in 

these connectors are live when the Apex 

is on.  These connectors are polarized, 1/4 

turn, locking connectors

CONTROL CONNECTOR

The control connector is a smaller 

4-pin version of the anode and cathode 

connectors (Figure 10). It is also polarized, 

and the smaller size prevents incorrect 

connections.  The Apex utilizes a low 

voltage control circuit for added safety. 

BATTERY COMPARTMENT AND CONNECTIONS

Figure 8

Use  Only  Smith-Root,  Inc.  Batteries  With T his  Unit. 

Install  Batteries  As  Sh own  Below. 

Battery 

Heavy-Duty 

Standard 

#6682 

#6681 

Lithium Iron

Phosphate

#10765 

Figure 9

Figure 10

Содержание APEX BACKPACK

Страница 1: ...11808 00 MANUAL APEX BACKPACK USER GUIDE USER S GUIDE A P E X B A C K PA C K...

Страница 2: ...on will be referred to the shipping company for insurance reimbursement 11808 00 MANUAL APEX BACKPACK USER GUIDE 2021 Smith Root Inc CONTENTS INTRODUCTION 4 OVERVIEW 5 APEX CONTROLS AND FEATURES 5 USE...

Страница 3: ...R SETTINGS 20 VOLTAGE ADJUSTMENT 20 DUTY CYCLE ADJUSTMENT 21 FREQUENCY ADJUSTMENT 21 WAVEFORM SETTING 22 DUAL WAVEFORM 22 USB FEATURES 23 DATA LOGGING 23 DOWNLOADING DATA 23 SOFTWARE UPDATES 23 SPECIF...

Страница 4: ...y and efficiently An immersion sensor automatically turns the output off if the bottom of the pack frame comes into contact with water The anode out of water detector automatically turns off the outpu...

Страница 5: ...ned for unit to function 6 Audio Alarms Sounds to indicate that the unit is on and to indicate modes or faults 7 Audio Alarms indicate modes or faults 8 USB Port For downloading data and updating soft...

Страница 6: ...FACE GUI The Apex Keypad Fig 4 is comprised of 7 buttons which are described as follow 1 Menu Button Pressing this button will take the user to the setting menu 2 6 Generic buttons used for various fu...

Страница 7: ...the peak power 7 Timer Elapsed time in seconds This value is incremented only when the output is active 8 Voltage Voltage setpoint of the out put To change this value see Voltage Adjustment on page 22...

Страница 8: ...r when the electrode out of water is detected See Anode Out of Water on page 14 for more detail C Power Limit this setting enables the user to select whether to sound an alarm when average power setpo...

Страница 9: ...unit to either sound an alarm or to go into foldback mode by reducing output voltage See page 14 Tempera ture Settings for more information B Display Mode Display can be either in Dark mode or Light m...

Страница 10: ...s connector is color coded and polarized to prevent accidental reverse connections of the battery ANODE AND CATHODE CONNECTORS The anode and cathode connectors are black plastic circular 2 pin connect...

Страница 11: ...s CAUTION Always unlatch the chest strap of the pack before entering or crossing water If left latched this strap may prevent the user from quickly removing the APEX in the event of an emergency such...

Страница 12: ...ow pitch at the rates specified above 4 Dual Output Mode In this mode the APEX can operate with a primary or secondary user specified voltage waveform combination The selection between the two combina...

Страница 13: ...ly dried before resetting the unit Figure 16 Detail showing immersion sensor ANODE OUT OF WATER This feature disables the output of the APEX and displays an error message whenever the anode pole switc...

Страница 14: ...heat being produced inside the system This can allow the unit to continue to work instead of waiting for it to cool down again This power reduction does not begin until the Apex is near the point of t...

Страница 15: ...a more appropriate voltage for the present conditions If this error is caused by a mistake for example temporarily having the Anode and Cathode too close together acknowledge the error message by rel...

Страница 16: ...until the tilt switch activates about 55 degrees and the tilt message appears on the display Straighten up and the status display should return If the tilt message does not appear do not use the unit...

Страница 17: ...the conditions and set up the waveform accordingly It should take a few seconds of running followed by three beeps of the audio tone indicating the completion of analysis 11 The Apex is now set up 12...

Страница 18: ...d swimming action The nerves have time to repolarize and the muscles have time to relax between output pulses of the electrofisher Tetany is locking up the muscles The fish is stiff and there may be s...

Страница 19: ...lays all the saved waveforms You may select any of the waveforms by pressing the corresponding button 4 You are ready to begin electrofishing 5 Observe the reactions of the fish It may be necessary to...

Страница 20: ...or decrease the number of seconds Once complete press BACK button to return to home screen A tonal alarm will activate once the noted amount of electrofishing effort elapses A reminder alarm will con...

Страница 21: ...hicker scaling This longer duty cycle will decrease the battery life but will generally increase capture efficiency FREQUENCY ADJUSTMENT Frequency adjustment determines the rate of electrical pulsing...

Страница 22: ...S button to store and recall settings Once complete press the BACK button to return to the home screen A Direct Current DC Continuous uninterrupted current flows from backpack between anode and cathod...

Страница 23: ...gure 35 Follow on screen prompts to remove USB flash drive All stored data on the backpack will load onto the USB flash drive as comma separated files These files can be opened by any editing software...

Страница 24: ...sher before damage can occur Reset automatically when condition is corrected Output Indicator Audio tone for 30 VDC and greater with increasing pulse rate for output power Flashing red light Status di...

Страница 25: ...ater or dust In order to avoid overheating the charger should not be covered when it is in use Chargers filled with molding material are splash proof but must not be immersed in water The socket shoul...

Страница 26: ...ut Power 60W Input Connection 3 pin IEC 320 input cord set not included Output Connection Red and black polarized connectors Dimensions Weight 5 31 x 3 15 x 1 73 135 x 80 x 44mm 0 77 lbs 350g WARNING...

Страница 27: ...even if the battery was only slightly discharged these batteries do not have a memory The total number of charge discharge cycles possible varies inversely with depth of discharge on each cycle Over d...

Страница 28: ...rging after each use 2 Extreme temperatures kill batteries Avoid storage in exceedingly warm or cold areas Recommended oper ating temperatures are between 5 and 35 degrees C maximum 15 to 50 degrees C...

Страница 29: ...e a charge Deep cycle batteries are capable of being charged and discharged from 100 up to 1 000 times depending on the depth of the discharge and the type of charger used Service life and shelf life...

Страница 30: ...31 APEX BACKPACK www smith root com SECTION 7 ELECTROFISHING SAFETY ELECTROFISHING SAFETY...

Страница 31: ...ical shock Make sure that Electrofisher gives audible sound when voltage is present at anode Quick release system is functioning properly Tilt switch is functioning properly turns output off Dipnets w...

Страница 32: ...damage The voltage is relevant because it is the force that pushes the current through the body Experiments show that 20 to 500 Hz AC current is more dangerous than DC or higher frequencies of AC The...

Страница 33: ...nd waders never touch an electrode while the circuit is energized Do not work on the electrical system while the pack is plugged in A severe electrical shock from electrofishing gear may result in the...

Страница 34: ...use to leave stop electrofishing load the equipment and leave the area WARNING Operating this equipment in a manner not specified in this manual making modifications or using accessories not approved...

Страница 35: ...e tabs on hip belt buckle to remove hip belt 2 Squeeze the release tabs on either shoulder strap 3 With strap detached shrug off opposite strap 4 This will allow the pack to fall away from you very qu...

Страница 36: ...37 APEX BACKPACK www smith root com APPENDIX...

Страница 37: ...NSION SYSTEM The LR 24 suspension system has a wide adjustment range to fit most people comfortably The standard suspension will fit 32 to 40 waists The suspension system can be adjusted for body leng...

Страница 38: ...on of back padding 8 Tuck the hook and loops under the upper section fitting the upper and lower sections snuggly together and press to secure the hook and loop together 9 Tuck the loops on each side...

Страница 39: ...2 The intensity of the electric field increases as the fish to electrode distance decreases Therefore the risk of injury to the fish is greatly increased with the use of an Anode ring net 3 Nets make...

Страница 40: ...sher and it should be returned to the factory for repair CATHODE TESTING 1 Set the multi meter to measure resistance and connect leads to the pins of the connector on the end of the cathode cable The...

Страница 41: ...etup with proper safety gloves non breathable waders and cord strain reliefs properly installed on either side of the battery compartment Note This is for illustration purposes only and no one should...

Страница 42: ...for the purpose of stunning fish Frequency The rate at which an electrical signal changes over time The unit of measure is the Hertz One Hertz is equal to one change cycle per second and is abbreviat...

Страница 43: ...info smith root com 360 573 0202 Vancouver WA USA www smith root com...