background image

General

The  Smith Meter

®

 Model UPT (Universal Pulse) Transmit-

ter is a photo-electric, dual channel, high resolution, pulse 
generator that is directly connected to the output shaft of a 
positive displacement meter.
The UPT Transmitter is installed at the lowest level in the 
meter accessory stack. It is designed to be mounted directly 
on the meter dome adaptor and replaces the manual cali-
brator. If other mechanical stack accessories are required,  
a calibrator adaptor kit is used for mounting the manual 
calibrator above the UPT Transmitter.

Reference Publications

Specification Bulletin 

SS01105

Parts List 

PO01056

 (P0907.05)

Receipt of Equipment

When the equipment is received, the outside packing case 
should be checked immediately for any shipping damage. 
If the packing case has been damaged, the local carrier 

should be notified at once regarding his liability. Carefully 

remove the unit from its packing case and inspect for  
damaged or missing parts.
If damage has occurred during shipment or parts are  
missing, a written report should be submitted to the Inside 

Sales Department, Measurement Solutions, PO Box 10428, 
Erie, Pennsylvania 16514.

Prior to installation, the unit should be stored in its original 
packing case and protected from adverse weather condi-
tions and abuse.

Mechanical Installation

When ordered with a Smith Meter

®

 positive displacement 

(PD) meter, the Model UPT Transmitter will normally be  
factory installed directly on the meter. The following steps 

are required for field mounting the UPT Transmitter to a 

Smith Meter PD meter: 

1.  Remove all accessories (counters, mechanical temperature 

compensators, transmitters, etc.) from the meter.

2.  Remove the existing calibrator, located inside the meter 

dome adaptor.

  a.  Remove the cap protecting the external calibrator 

 

  adjusting stem by removing the two mounting screws.

  b.  Indicate the calibrator setting with a line that intersects the  

  calibrator dial and its adjacent part.

  c.  Remove the calibrator adjusting assembly by removing    

  the two mounting screws and carefully withdraw the stem  
  assembly from the housing without changing the adjusting  
 screw. 

  d.  Remove the calibrator from the meter dome adaptor by    

  removing the two small hold-down screws and carefully    
  rotating the calibrator body clockwise.

  e.  Attach the blind plate (provided in the adaptation  

  kit) over the calibrator stem assembly hole.

Universal Pulse Transmitter (UPT) 

Installation/Service

Bulletin MN01045 Issue/Rev. 0.7 (11/17)

MANUAL

Содержание UPT

Страница 1: ...nnsylvania 16514 Prior to installation the unit should be stored in its original packing case and protected from adverse weather condi tions and abuse Mechanical Installation When ordered with a Smith...

Страница 2: ...ed 10 If desired a seal wire can be installed like a belt around the middle of the UPT Transmitter cover and housing to prevent unauthorized tampering with internals Note With the calibrator removed f...

Страница 3: ...nnections Rotation of Transmitter Shaft Reference Dimensions Drawing Below Electronics Ground white 1 Input Power 12 24 Vdc brown 2 Counter Clockwise Clockwise Channel B Output grey 3 Leading Lagging...

Страница 4: ...acket from enclosure b Remove screws holding T Bar in place 1 2 3 4 5 6 7 8 9 9 8 7 6 5 4 3 2 1 Step 4a Step 4b Step 3 Remove the coupling and pull the shaft out Step 2 a Remove hairspring cotter pin...

Страница 5: ...minal block Step 7 Inspect terminal block and encoder for damage corrosion or wear and replace if needed Step 6 Step 8 a Re insert o ring tighten cover over o ring and then tighten aluminum piece with...

Страница 6: ...m is approximately 1 8 above the T bar base Note Ensure that the washer is between the cotter pin and the housing Apply a light coat of Loctite 222 included to the set screw threads prior to tightenin...

Страница 7: ...l corrosion protection to the flame path TechnipFMC synthetic grease P N 644886401 is recommended Apply a nickel based anti size lubricant to all cover fasteners TechnipFMC P N 646002401 is recommende...

Страница 8: ...moisture can enter into the UPT housing TechnipFMC com TechnipFMC 2017 MN01045 Issue Rev 0 7 11 17 TechnipFMC FMC Technologies Measurement Solutions Inc 500 North Sam Houston Parkway West Suite 100 Ho...

Отзывы: