background image

POSYC 3303 industrial PC

Installation, use and maintenance manual - EN

Ver. 1.02

29 

Pay attention to the way in which the new battery is inserted in its slot, respecting the polarity as shown in the

following image:

If the existing battery is not completely discharged, performing the replacement operation in a few seconds, it

will not be necessary to correct the date / time of the CMOS Setup.

9.3 CFast replacement

If it is necessary to replace the 32GB CFast flash disk (KE050087), the BIOS automatically changes its Boot

settings. To allow the POSYC to be properly set up with the operating system installed on the new CFast, or

Windows 10, it is necessary to modify the BIOS/CMOS parameters as described below:

•  Boot

•  Boot Option #1

•  UEFI: Built-in EFI Shell 

replace with

 Windows Boot Manager (P0: CFast 3ME4)

•  Boot

•  Boot Option #2

•  UEFI: Built-in EFI Shell 

replace with

 Disabled 

Positive polarity (+)

Negative polarity (-)

Содержание POSYC 3303

Страница 1: ...Italy www smitec it Installation use and maintenance manual INDUSTRIAL COMPUTERS POSYC 3303 BEFORE STARTING UP THE POSYC 3303 INDUSTRIAL PC CAREFULLY READ THIS MANUAL AND FOLLOW ALL INSTRUCTIONS IN OR...

Страница 2: ...side view 15 6 2 24V IN supply connector 17 6 3 RS485 serial port COM1 19 6 4 Ethernet connectors 20 6 4 1 LED behavior for signaling of communication speed 20 6 4 2 LED behavior for signaling connect...

Страница 3: ...ollowing professionals The present instructions must be made available to all the above individuals User User is a person a company or an institution that buys the equipment and uses it for the purpos...

Страница 4: ...of behaviors and obligations to be complied with while DO NOT USE THE EQUIPMENT NOR MAKE ANY INTERVENTION BEFORE INTE GRALLY READING AND UNDERSTANDING THIS MANUAL IN PARTICULAR ADOPT ALL SAFETY PRECA...

Страница 5: ...e and maintenance manual EN Ver 1 02 5 performing the activities described later on in this manual These prescriptions constitute the prescribed method of operating the device in a way that is safe fo...

Страница 6: ...the drawings in this manual might have been modified later always refer to the latest version All upgrades can be requested to SMITEC S p A directly Make sure that the personnel is qualified and adeq...

Страница 7: ...ul for standard devices Since it is sufficient to exert a slight pressure with a finger on its surface to make an immediate pointing this system is the main User Friendly feature of the POSYC computer...

Страница 8: ...POSYC 3303 industrial PC Installation use and maintenance manual EN Ver 1 02 8 4 1 Front view...

Страница 9: ...te when this manual was drawn up To improve or update this product SMITEC S p A reserves the right to modify its technical features without notice Operating temperature 0 50 C when it is operating Sto...

Страница 10: ...ications 5 3 1 Front view The computers Posyc 3303 need to be fixed on a stable and rigid panel provided with 4xM3 metal threaded hole min 1 5mm deep Use 4xM3x10mm Fe Zn not countersunk head type scre...

Страница 11: ...POSYC 3303 industrial PC Installation use and maintenance manual EN Ver 1 02 11 5 3 2 Side view...

Страница 12: ...POSYC 3303 industrial PC Installation use and maintenance manual EN Ver 1 02 12 5 3 3 Rear view recommended panel cut...

Страница 13: ...are Processor Intel Celeron Quad Core N3160 1 60GHz Memory 4GB DDR3 1600MHz RAM CFast card 32GB Display 7 color LED TFT 800x480 262K colors Touch screen sensor 4 resistive wires Touch screen controlle...

Страница 14: ...ered separately like the other accessories not included in the POSYC 321X Here is a list of the order codes Order codes Model Description KZ010495 3303 POSYC 3303 Order codes Merchandise KF101074 24VD...

Страница 15: ...s shown in the following figures 6 1 Connections side view Name Function COM1 RS485 serial communication port DP DisplayPort video port ETH1 Ethernet communication port 1 ETH2 Ethernet communication p...

Страница 16: ...al PC Installation use and maintenance manual EN Ver 1 02 16 Name Function PWR LED White LED signaling POSYC on HDD LED White LED signaling activity CFast Name Function BAT CR2032 button battery slot...

Страница 17: ...n in accordance with EN VDE Solid min 0 14mm Rated voltage 320V Solid max 1 5mm Rated current 8A Stranded min 0 14mm Stranded max 1 5mm Insulating material PA Stranded with ferrule without plastic sle...

Страница 18: ...y the cable itself To ensure compliance with the EMC 2014 30 EU directive the length of the cables must not exceed a length of 30 meters The POSYC 3303 is a high tech electronic device sensitive to el...

Страница 19: ...un incendie en rai son de ph nom nes de surchauffe g n r s par le c ble lui m me Pour garantir la conformit avec la directive EMC 2014 30 EU la longueur des c bles ne doit pas d passer 30 m tres Le P...

Страница 20: ...g to the speed at which the Ethernet port is communicating the LED takes on a different color The second orange marked by the letter A indicates the state of activity of the door itself or if the door...

Страница 21: ...C the CFast memory card connector is instead found The memory is secured inside the computer by blocking a lever 6 6 Battery slot At the top of POSYC there is instead the slot where the CR2032 button...

Страница 22: ...unless you are equipped with suitable static electricity protection equipment any discharges on the con nectors could damage the appliance Since the front panel integrates the touch screen sensor viol...

Страница 23: ...by the use of standard computer connectors this means that all standard peripheral for personal computers can be connected by means of the cable supplied with them or by means of commercial cables ea...

Страница 24: ...istors with a value of 120ohm for the beginning and end of the section the master and the most remote slave are considered respectively called 1 and 4 in the figure below The length of the cable conne...

Страница 25: ...the waveforms detected by means of an oscilloscope in different connection situa tions Example of a correct signal Example of a signal with unfinished lines Example of a signal with placed termination...

Страница 26: ...clicking and right mouse button Refer to the software manual for further details 8 2 CFast card The CFast card of the POSYC replaces the traditional hard disk thus ensuring better shock tolerance and...

Страница 27: ...ces in fact the new devices that were not pres ent at the previous start up are listed as the last ones in the start up sequence From this it follows that for example by replacing the CFast that conta...

Страница 28: ...The replacement of the internal clock battery in addition to ensuring the maintenance of the same is useful not to lose the settings of the CMOS Setup basic information for the operation of the compu...

Страница 29: ...correct the date time of the CMOS Setup 9 3 CFast replacement If it is necessary to replace the 32GB CFast flash disk KE050087 the BIOS automatically changes its Boot settings To allow the POSYC to be...

Страница 30: ...opens automatically Confirm with the Yes keyboard 9 4 BIOS update If it is necessary to reinstall the BIOS via a dedicated USB key change the BIOS CMOS parameters as de scribed below Boot CSM Support...

Страница 31: ...the event that there is a loss of memory of the CMOS Setup for example after the backup battery has been used up the parameters are automatically restored when the POSYC starts up with the exception o...

Страница 32: ...COM1 13 19 CR2032 14 21 28 D Display 13 DP 7 13 E Ethernet 7 13 20 F Fastening 10 FE 18 Front view 8 10 H Handling 6 HDD LED 16 HDMI 7 13 15 HMI 7 I Installation 22 L LAN 13 LEDs 15 M Memory 13 Mercha...

Отзывы: