The servo-drives/inverters of the COSMOS 302X series generate a certain quantity of heat during operation;
the electrical panel must be able to dissipate it, in order to avoid an excessive temperature increase. A common
solution consists in installing cooling fans or a conditioner. In order to avoid dust ingress, which might degrade
the dissipater performance, it is recommended to use filters. The conditioning system must be adequately sized
by taking into consideration the total dissipation.
In order to ensure the performance characteristics, the servo-drives/inverters of the COSMOS 302X series
must be installed exclusively in vertical position (as indicated in the previous picture), leaving at least 100mm
of obstacle-free space above and below the driver. If such conditions could not be fulfilled, apply a derating of
the available current.