Operator’s Manual
HP50GC Pellet Stove
~ 11 ~
VENTING
Before venting, consult vent manufacturer
’
s
specifications and recommendations for all venting
installations.
The following installation guidelines must be followed
to ensure conformity with both the safety listing of
this stove and to local building codes
.
TYPE OF VENT
The pellet venting pipe (also known as L vent) is
constructed of two layers with air space between
the layers. This air space acts as an insulator and
reduces outside surface temperature of pipe to allow
a clearance to combustibles.
A cap must be used at
the termination of type L vent chimneys. For
elevations above 2,500 feet above sea level, a 4
”
L
is required.
PELLET VENT INSTALLATION
Vent termination MUST exhaust above air inlet
elevation. It is recommended to install at least three feet
(3’) of vertical
pellet vent pipe.
This vertical pipe will create some
natural draft to prevent the possibility of smoke or odor during
appliance shutdown and will keep exhaust from causing a nuisance or
hazard from exposure to high temperatures.
The installation must include a clean out tee to enable
collection of fly ash and to permit periodic cleaning of
the exhaust system. Total length of horizontal vent
must not exceed 10 feet. The
maximum recommended vertical
venting height is 18 feet.
All joints for pellet vent are required to be
fastened with at least three screws and all
pellet
vent connections
(including adapters,
elbows,
etc.) should be sealed airtight
by injecting 500 F. RTV silicone into the
gap between sections.
The area where the vent pipe goes
through to the
exterior of the home must be
sealed with silicone or other means to maintain the
vapor barrier between the exterior and the interior of
the home.
WARNING
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE
SERVING ANOTHER APPLIANCE.
DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST
VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT DIRECTLY TO A MASONRY
CHIMNEY.
DO NOT TERMINATE VENT IN ANY ENCLOSED
OR
SEMI-ENCLOSED AREA, SUCH AS; CARPORTS,
GARAGE, ATTIC, CRAWL SPACE, UNDER A SUN DECK OR
PORCH, NARROW WALKWAY OR CLOSED AREA, OR ANY
LOCATION THAT CAN BUILD UP A CONCENTRATION OF
FUMES SUCH AS A STAIRWELL, COVERED BREEZEWAY ETC
VENT
SURFACES
CAN
GET
HOT
ENOUGH
TO
CAUSE
BURNS
IF
TOUCHED.
N
ONCOMBUSTIBLE
SHIELDING
OR
GUARDS
MAY
BE
REQUIRED.
PELLET
VENT
MUST
MAINTAIN
MINIMUM
CLEARANCES
SPECIFIED
BY
VENT
MANUFACTURER
FOR
CLEARANCE
TO
ANY
COMBUSTIBLES.
INSTALL
VENT
AT
CLEARANCES
SPECIFIED
BY
THE
VENT
MANUFACTURER.
ALL
VENTING,
WHETHER
VERTICAL
OR
HORIZONTAL, JOINT
S
SHOULD
BE
M
ADE
GAS-TIGHT
WITH
RECOMMENDED
SEALANTS.