- 12 -
4. Operation
4.1 Display and Keys
The PLUR series is displayed with the Graphical LCD, and it has three
keys, with its functions as follow:
Keys
Functions
SEL
1: Go into the next level menu or program
2: Saves the current Settings
3: Switch the measurement page
INC
1. Select the menu from up to down in turn;
2. Adjust the parameters of a particular value (0 ~ 9)
MOV
1. Cycle select other parameters
2. Cycle select other digit of a value.
MOV+SEL
Short Press
1. Go from the running Mode into the programming Mode.
2. Exit from the setting program to the last menu,or return the
Main Menu to the Running Mode.
MOV+SEL
Long Press
6 seconds
Restart the instrument.
4.2 Two working mode
The instrument has two working mode: running mode and programming
mode. In running mode, the measurement data is displayed. In
programming mode, user can setup parameters of the instrument.
4.2.1
Running mode
When the power is turned on, the instrument takes several seconds to
initialize and then runs into the running mode to start the normal level
measurement.
In the running mode, the level meter shows the level measurement, in
which the state contains 2 pages: the main measuring page and other
measurement information page, press SEL key to quickly switch two
pages. The main measuring page can display the level value/distance