Installation
81
EN
Gas types and Countries
Burner and nozzle characteristics tables
Gas types
IT
GB-IE FR-BE DE
AT
NL
ES
PT
SE
RU
DK
PL FI-NO
1 Natural Gas G20
G20
20 mbar
•
•
•
•
•
•
•
•
•
•
•
•
G20/25
20/25 mbar
•
2 Natural Gas G25.3
G25.3
25 mbar
•
3 Natural Gas G25
G25
20 mbar
•
4 Natural Gas G2.350
G2.350
13 mbar
•
5 LPG G30/31
G30/31
28-30/37 mbar
•
•
•
•
•
•
G30/31
30/30 mbar
•
•
•
•
6 LPG G30/31
G30/31
37 mbar
•
7 LPG G30/31
G30/31
50 mbar
•
•
8 Town gas G110
G110
8 mbar
•
•
•
1 Natural Gas G20
AUX
SR
UR2
Rated heating capacity (kW)
1.0
1.8
4.2
Nozzle diameter (1/100 mm)
72
97
145
Pre-chamber (printed on nozzle)
(X)
(Z)
(F3)
Reduced flow rate (W)
400
500
1200
2 Natural Gas G25.3
AUX
SR
UR2
Rated heating capacity (kW)
1.0
1.8
4.2
Nozzle diameter (1/100 mm)
72
94
143
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F2)
Reduced flow rate (W)
400
500
1200
3 Natural Gas G25
AUX
SR
UR2
Rated heating capacity (kW)
1.0
1.8
4.1
Nozzle diameter (1/100 mm)
77
100
165
Pre-chamber (printed on nozzle)
(F1)
(Y)
(H3)
Reduced flow rate (W)
400
500
1200