Smeg Victoria SR975BGH Скачать руководство пользователя страница 19

Instructions for the installer

43

9.3

Adjustment for city gas

Carry out the same steps as described in “9.2 Adjustment for LPG”, but select the
nozzles and adjust the primary air for city gas as indicated in the table below and in
"9.5 Primary air adjustment”.

Warning:

Only units with safety valves can be used with city gas G110.

Burner

Rated

heating

capacity

(kW)

City gas – G110

8 mbar

Nozzle diameter

1/100 mm

Reduced capacity

(W)

Auxiliary (1)

1.05

132

380

Semi-rapid (2)

1.65

165

380

Medium rapid (3)

2.55

210

650

Large Rapid (4)

3.1

240

750

Ultra-rapid (5)

3.3

250

1200

Double crown

Internal (6)

1.05

132

380

External (6)

3.9

290

1200

Fish burner

2

190

750

The values for city gas refer to appliances in category III 1a2H3+.

9.4

Adjustment for natural gas

The hob is preset for

natural gas G20

(2H) at a pressure of 20 mbar. To reset the

appliance for operation with this type of gas, carry out the same steps as described
in “9.2 Adjustment for LPG”, but select the nozzles and adjust the primary air for
natural gas as indicated in the table below and in "9.5 Primary air adjustment”. After
the adjustments have been carried out, restore the seals with sealing wax or
equivalent material.

Burner

Rated

heating

capacity

(kW)

Natural gas – G20

20 mbar

Nozzle diameter

1/100 mm

Reduced capacity

(W)

Auxiliary (1)

1.05

73

380

Semi-rapid (2)

1.65

92

380

Medium rapid (3)

2.55

115

650

Large Rapid (4)

3.1

126

750

Ultra-rapid (5)

3.3

130

1200

Double crown

Internal (6)

1.05

73

380

External (6)

3.9

140

1200

Fish burner

2

100

750

Содержание Victoria SR975BGH

Страница 1: ...eaning and maintenance of the appliance INSTRUCTIONS FOR THE INSTALLER these are intended for the qualified technician who must install the appliance set it functioning and carry out an inspection tes...

Страница 2: ...OTHER THAN AS INDICATED IF THE APPLIANCE IS INSTALLED ON BOATS OR IN CARAVANS DO NOT USE IT AS A ROOM HEATER DO NOT USE THIS APPLIANCE FOR HEATING ROOMS THIS APPLIANCE IS MARKED ACCORDING TO EUROPEAN...

Страница 3: ...AT THE CONTROL KNOBS ARE IN THE OFF POSITION WHEN YOU FINISH USING THE HOB NEVER PLACE PANS WITH BOTTOMS WHICH ARE NOT PERFECTLY FLAT AND SMOOTH ON THE COOKING HOB RACKS NEVER USE CONTAINERS WHICH PRO...

Страница 4: ...FORE CARRYING OUT INSTALLATION MAINTENANCE WORK MAKE SURE THAT THE APPLIANCE IS NOT CONNECTED TO THE POWER GRID THE PLUG TO BE CONNECTED TO THE POWER SUPPLY CABLE AND ITS SOCKET MUST BE OF THE SAME TY...

Страница 5: ...COULD REACH THE ELECTRONICS DAMAGING THEM AND CAUSING SHORT CIRCUITS DO NOT MODIFY THIS APPLIANCE DO NOT SPRAY ANY SPRAY PRODUCTS NEAR THE ELECTRICAL APPLIANCE WHILE IT IS IN OPERATION DO NOT USE SPR...

Страница 6: ...r results in the application of administrative sanctions The product does not contain substances in quantities sufficient to be considered hazardous to health and the environment in accordance with cu...

Страница 7: ...mum flame symbol until it lights On valved models hold down the knob for about 2 seconds to keep the flame lit and to activate the safety device The burner may go out when the knob is released If this...

Страница 8: ...1 Auxiliary 7 18 2 Semi rapid 10 24 3 Medium Rapid 12 24 4 Large Rapid 14 26 5 Double crown ultra rapid 12 28 6 Triple crown ultra rapid 22 28 7 Fish burner Suitable oval containers For burner referen...

Страница 9: ...ry daily cleaning To clean and preserve surfaces always use only specific products that do not contain abrasives or chlorine based acids How to use pour the product onto a damp cloth and wipe the surf...

Страница 10: ...ese components must not be washed in the dishwasher 5 2 3 Flame spreader crowns The flame spreader crowns are removable Wash them with hot water and non abrasive detergent making sure to remove any en...

Страница 11: ...he cooktop remove the lid unit by lifting it upwards When finished cleaning refit the cover making sure to insert it correctly Before lifting up the lid dry out any liquid that may have dripped Never...

Страница 12: ...e counte A mm B mm C mm D mm E mm L mm X mm Y mm min 145 min 460 min 750 20 40 min 50 690 555 560 478 482 Carefully position the supplied insulating seal on the outer perimeter of the hole made in the...

Страница 13: ...an empty kitchen unit with doors a separation panel must be placed under the hob Keep a minimum distance of 10 mm between the bottom of the hob and the surface of the panel which must be easily extrac...

Страница 14: ...equal to or greater than 3 mm in an easily accessible position close to the appliance Avoid use of adapters and shunts If the power cable is replaced the cross section of wires in the new cable must b...

Страница 15: ...eset for natural gas G20 2H at a pressure of 20 mbar For supplying it with other types of gas see chapter 9 ADAPTATION TO DIFFERENT TYPES OF GAS The gas inlet connection is threaded for external gas I...

Страница 16: ...protected by grills must be the right size to comply with current regulations and positioned so that no part of them is obstructed not even partially The room must be kept adequately ventilated in ord...

Страница 17: ...e replaced and the primary air must be adjusted In order to replace the nozzles and adjust the burners the hob top must be removed as described below 9 1 Removing the hob top 1 Remove all the knobs pa...

Страница 18: ...5 Primary air adjustment and then secure the tube by means of screw A After the adjustments have been carried out restore the seals with sealing wax or equivalent material Burner Rated heating capaci...

Страница 19: ...0 The values for city gas refer to appliances in category III 1a2H3 9 4 Adjustment for natural gas The hob is preset for natural gas G20 2H at a pressure of 20 mbar To reset the appliance for operatio...

Страница 20: ...hob 9 6 Final operations After making the adjustments described above reassemble the appliance by following the instructions in 9 1 Removing the hob top in reverse order 9 6 1 Adjusting the minimum fo...

Страница 21: ...e tap rod depending on the model fully in a clockwise direction The bypass diameters for each individual burner are shown in table 9 2 Adjustment for LPG After adjustment with a gas other than the pre...

Страница 22: ...id 5 Triple crown ultra rapid 6 Double crown ultra rapid 7 Fish burner 9 8 Lubrication of gas taps Over time the gas taps may become difficult to turn and get blocked Clean them internally and replace...

Отзывы: