Installation
35
EN
Burner and nozzle characteristics tables
1 Natural Gas G20
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
72
97
115
140
Pre-chamber (printed on nozzle)
(X)
(Z)
(Y)
(-6)
Reduced flow rate (W)
400
500
800
1600
2 Natural gas G20 – 25 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
72
94
113
128
Pre-chamber (printed on nozzle)
(X)
(Z)
(-1)
(S)
Reduced flow rate (W)
400
500
800
1600
3 Natural gas G25 – 25 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
72
94
121
138
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F2)
(F3)
Reduced flow rate (W)
400
500
800
1600
4 Natural gas G25.1 – 25 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
77
100
134
145
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1600
5 Natural gas G25 – 20 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
77
100
134
145
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1600
6 Natural gas G27 - 20 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.1
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
77
105
138
152
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1600
7 Natural gas G2.350 – 13 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
3.0
3.6
Nozzle diameter (1/100 mm)
94
120
165
200
Pre-chamber (printed on nozzle)
(Y)
(Y)
(F3)
(H2)
Reduced flow rate (W)
400
500
800
1600