Instructions for the installer
• Use H05V2V2-F cables resistant to at least 90°C.
• The values indicated above refer to the cross-section of the internal conductor.
• The tightening torque of the screws of the terminal supply wires must be 1.5 - 2 Nm.
• The aforementioned power cables are sized taking into account the coincidence factor (in compliance
with standard EN 60335-2-6).
11.5 Positioning the skirt (on some models only)
The skirt must always be positioned and secured correctly
on the appliance.
1 Unscrew the 2 nuts (
B
) on the back of the worktop.
2 Position the skirt above the worktop, taking care to align
the pins (
C
) with the holes (
D
).
3 Secure the skirt to the worktop by tightening screws (
A
).
11.6 Positioning and levelling the appliance
After making the electrical and/or gas connections, level the
appliance on the floor by means of its four adjustable feet.
First insert the front feet and then the rear feet.
The appliance must be properly levelled to ensure better
stability. Screw or unscrew the bottom part of the foot until
the appliance is stable and level on the floor.
To prevent possible damage to the appliance, we recommend to screw the front feet first and then the
rear ones.