The appliance can work in the following
modes:
•
220-240 V 1N
~
3 x 1.5 mm²
three-core
cable.
Fixed connection
Fit the power line with an omnipolar circuit
breaker in compliance with installation
regulations.
The circuit breaker should be located near
the appliance and in an easily reachable
position.
Connection with plug and socket
Make sure that the plug and socket are of
the same type.
Avoid using adapters and shunts as these
could cause overheating and a risk of
burns.
Positioning and levelling
• After making the gas and electrical
connections, screw on the four feet
supplied with the appliance.
The appliance must sit level on the floor to
ensure stability.
• Screw or unscrew the bottom part of the
foot until the appliance is stable and
level on the floor.
The values indicated above refer
to the cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).