9. GAS CONNECTION

This appliance is suitable for installation with
Natural Gas or ULPG (propane). Refer to page
12 for the relevant burner pressure and
appropriate injector sizes. When the appliance is
to be connected to Natural Gas then the
pressure regulator supplied must be fitted to the
gas inlet. A test point (for checking the gas
pressure) is supplied either with the regulator or
as a separate fitting in the case of ULPG
(propane) appliances. Connection of the
appliance to the gas supply must be in
accordance with the requirements of AS5601. A
½” BSP connector at the inlet is recommended
and the gas supply line to the appliance must be
of adequate length to allow sufficient withdrawal
of appliance for service or disconnection and be:

1

annealed copper pipe or;

2

flexible hose according to AS/NZ1869 & be at least Class “B”, 10 mm
diameter.

The appliance must be installed with provision to allow the gas to be
turned off and disconnected for servicing and removal of the appliance as
required from the gas supply. Before the appliance is operated make
certain all relevant parts are placed in the correct position. When the
installation is completed the installation connections of appliance will
require to be leak tested, the burner operating pressure and flame
checked and adjusted. Warranty service calls do not cover these
adjustments! To check the operating pressure of the appliance it is
recommended at least 2 large size burners are used. Ensure appliance is
secured to wall when installation is completed. N.G. The regulator
supplied must be fitted to the ½ BSP thread at the rear of the appliance.
An approved manual shut-off valve must be installed. The N.G. regulator
must be checked and adjusted to 1.0 kPa after installation.

U.L.P.G. 

Can be connected to the inlet fitting

directly. The pressure must be checked to ensure
it is operating at 2.75kPa. A separate test point
fitting must be installed between the piping & the
appliance for the pressure to be checked to
ensure it is operating at 2.75kPa.

Содержание SNL900XGF

Страница 1: ...intended for the qualified engineer who is to install commission and test the appliance 1 PRECAUTIONS FOR USE 4 2 DISPOSAL INSTRUCTIONS OUR ENVIRONMENT POLICY 5 3 SAFETY PRECAUTIONS 6 4 GETTING TO KN...

Страница 2: ...BOVE NEVER USE THIS APPLIANCE FOR HEATING ROOMS NEVER USE PACKAGING RESIDUES UNATTENDED IN THE HOME SEPARATE THE VARIOUS WASTE PACKAGING MATERIALS BY TYPE AND CONSIGN THEM TO THE NEAREST SEPARATE DISP...

Страница 3: ...for the addresses of collection recycling and disposal facilities Never leave all or part of the packaging lying around Packaging parts and especially plastic bags may represent a suffocation hazard...

Страница 4: ...ECT THE PLUG BY PULLING ON THE POWER SUPPLY LEAD THE APPLIANCE MUST BE CONNECTED TO EARTH IN COMPLIANCE WITH ELECTRICAL SYSTEM SAFETY REGULATIONS IMMEDIATELY AFTER INSTALLATION CARRY OUT A QUICK TEST...

Страница 5: ...type and consign them to the nearest separate disposal centre The inside of the appliance should be cleaned to remove all manufacturing residues For further information see point 6 USING THE HOB When...

Страница 6: ...until the burner lights If it does not light within the first 15 seconds turn the knob to 0 and wait at least 60 seconds before trying to light the burner again On models equipped with valves once th...

Страница 7: ...gh to prevent the liquid from boiling over When cooking to prevent burns or damage to the hob all pans or griddle plates must be placed inside the perimeter of the hob Take the greatest care when usin...

Страница 8: ...2 Food stains or spills Never use metal scouring pads or sharp scrapers which will damage the surface Use ordinary non abrasive products for steel with the aid of wooden or plastic utensils if necessa...

Страница 9: ...e work surface observing a minimum distance of 50 mm from the rear edge The lower part of the protective cover must be fully accessible when the appliance is installed This appliance can be installed...

Страница 10: ...e supporting structure do not use mechanical or electric screwdrivers and apply only moderate pressure to the fixing components by hand Important when fixing the product always use the brackets provid...

Страница 11: ...e less than 600 mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area in accordance with Clause 5 12 1 2 However in no case shall this cleara...

Страница 12: ...accordance with current regulations For proper operation of a gas appliance it is essential for the air necessary for combustion of the gas to be able to flow naturally into the room Air must flow di...

Страница 13: ...on to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are pl...

Страница 14: ...least 3 mm located in an easily accessible position close to the appliance itself If a socket and plug connection is used check that they are of the same type Do not use reducers adapters or junction...

Страница 15: ...types of gas the burner nozzles have to be changed and the gas taps adjusted to set the minimum flame To replace the nozzles proceed as described below 10 1 Changing the hob nozzles 1 Remove the pan...

Страница 16: ...or mm Auxiliary 1 3 9 0 54 Semi rapid 2 6 3 0 68 Rapid 3 10 8 0 85 Ultra rapid 4 15 0 1 05 Burner NG 1 0 kPa Nominal gas Consumption MJ h Injector mm Auxiliary 1 3 9 0 90 Semi rapid 2 7 5 1 20 Rapid 3...

Страница 17: ...screw inside or beside the tap rod depending on the model until an even minimum flame is obtained Put the knob back in place and check the stability of the burner flame the flame must not go out when...

Страница 18: ......

Страница 19: ......

Страница 20: ...914772987 B...

Отзывы: