background image

 

 

 

 

 

EN 

3

 

RECOMMENDATIONS AND SUGGESTIONS

 

  The Instructions for Use apply to several versions of this appliance. Accordingly, you may find 

descriptions of individual features that do not apply to your specific appliance. 

INSTALLATION 

•  The manufacturer will not be held liable for any damages resulting from incorrect or improper 

installation. 

•  The minimum safety distance between the cooker top and the extractor hood is 650 mm (some 

models can be installed at a lower height, please refer to the paragraphs on working dimensions 

and installation). 

•  Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of 

the hood. 

•  For Class I appliances, check that the domestic power supply guarantees adequate earthing. 

  Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route 

of the flue must be as short as possible. 

•  Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, 

etc.). 

•  If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a 

sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of 

exhaust gas. The kitchen must have an opening communicating directly with the open air in order 

to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances 

supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 

mbar to prevent fumes being drawn back into the room by the cooker hood. 

•  In the event of damage to the power cable, it must be replaced by the manufacturer or by the 

technical service department, in order to prevent any risks.  

  “WARNING: Failure to install the screws or fixing device in accordance with these instructions may 

result in electrical hazards.” 

USE 

•  The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. 

•  Never use the hood for purposes other than for which it has been designed. 

•  Never leave high naked flames under the hood when it is in operation. 

•  Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not 

engulf the sides. 

•  Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. 

•  Do not flambè under the range hood; risk of fire  

•  This appliance is not intended for use by persons (including children) with reduced physical, sen-

sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-

pervision or instruction concerning use of the appliance by a person responsible for their safety. 

•  Children should be supervised to ensure that they do not play with the appliance. 

• “WARNING: Accessible parts may become hot when used with cooking appliances.”. 

MAINTENANCE 

•  Switch off or unplug the appliance from the mains supply before carrying out any maintenance 

work. 

•  Clean and/or replace the Filters after the specified time period (Fire hazard). 

•  Clean the hood using a damp cloth and a neutral liquid detergent. 

 

The symbol 

 on the product or on its packaging indicates that this product may not be treated as household waste. Instead it 

shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product 
is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could 
otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, 
please contact your local city office, your household waste disposal service or the shop where you purchased the product. 

 

 

Содержание SHIG910X

Страница 1: ...Instructions Manual SHIG910X ...

Страница 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 10 MAINTENANCE 11 EN ...

Страница 3: ...ks WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure ...

Страница 4: ...EN 4 4 CHARACTERISTICS Dimensions 650mm minimum ...

Страница 5: ...ø 150 120 mm 10 1 Dumper 14 1 1 Air Outlet Connector Extension 15 1 Air Outlet Connector 24 1 Connection box 25 Pipe clamps not included 26 2 Cable clamps 27 1 Finishing plug Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12c 6 Screws 2 9 x 6 5 12e 2 Screws 2 9 x 9 5 12f 2 Screws M4 x 80 12g 4 Screws M6 x 80 12h 4 Screws 5 2 x 70 12q 4 Screws 3 5 x 9 5 21 1 Drilling template 22 8 6 4 mm int...

Страница 6: ...ings with wall thickness of 20 mm drill ø 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet Ducted Version drill according to the diameter of the external air ex haust duct connection Insert two screws of the following type crossing them and ...

Страница 7: ...do not come out of their seats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base is stable even if the frame is sub jected to bending In all cases where the ceiling is not strong enough at the suspension point the installer must provide strengtheni...

Страница 8: ...f the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Otherwise remove the lower chimney and adjust the position by inverting the extension pieces for air outlet connection 14 1 or by cutting the hood body extension piece 14 if any along one of the chases destined to the predetermined extension lengths Replace then the elements as earlier described Fit the di...

Страница 9: ...med on the galva nized diffuser support as shown in fig 2 Position the finishing plug 27 over the housing in the diffuser support fixing it us ing a screw 12e 2 9 x 9 5 and applying the 2 cable clamp elements 26 as indicated in figs 3 and 4 Connect the Controls Connector fig 5 Connect the Lighting Connector fig 6 Store both the Connectors in the Protective box 24 and close it with 2 Screws 12e 2 9...

Страница 10: ...aturation of the activated charcoal filters T2 Turn the suction motor on at speed two On Press and hold for approximately 5 seconds with all the loads turned off Motor and Lights to enable disable the Remote control 2 flashes Remote control Enabled 1 flash Remote control Disabled T3 Turn the suction motor on at speed three On Press and hold the button for 2 seconds to activate intensive speed This...

Страница 11: ...or more frequently if use is particularly intensive Resetting the alarm signal Press button T1 see the paragraph on Use Cleaning the Filters Remove the Filters one at a time pushing them towards the back of the unit and at the same time pulling downward Wash the Filters without bending them and leave them to dry completely before replacing Replace taking care to ensure that the handle faces forwar...

Страница 12: ...ctivated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press button T1 see the paragraph on Use Changing the Filter Remove the Metal grease filters Remove the saturated Activated Charcoal filter as shown in the figure Fit the new Filter hooking it into place Replace the Metal grease filters Lighting LIGHT REPLACEMENT 20 W halogen li...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...436006013_ver2 ...

Отзывы: