background image

 

 

 

 

 

EN 

1

10 

USE

 

L

T1

T2

T3

T4

L1

L2

L3

L4

Control panel 

Button Function 

Led 

Turns the lighting system on and off. 

-  

 

Press and hold for approx. 2 seconds to turn the 
lighting system on and off at reduced intensity. 

T1 

Turn the suction motor on and off at speed one.   On. 

 

Press and hold the button for approximately 2 
seconds, with all the loads turned off (Motor 
and Lights), to reset the Filters and turn off the 
Leds that are lit.  

After 100 working hours all the LEDs 
(L1-L2-L3-L4) will light up and remain 
lit to indicate saturation of the metal 
grease filters.  

After 200 working hours all the LEDs 
(L1-L2-L3-L4) will light up and start to 
flash to indicate saturation of the 
activated charcoal filters. 

T2 

Turn the suction motor on at speed two.  

On. 

 

Press and hold for approximately 5 seconds, 
with all the loads turned off (Motor and Lights), 
to enable/disable the Remote control.  

2 flashes, Remote control Enabled. 

1 flash, Remote control Disabled. 

T3 

Turn the suction motor on at speed three. 

On.  

 

Press and hold the button for 2 seconds to 
activate intensive speed. This speed is timed to 
run for 10 minutes. At the end of this time the 
system will automatically return to the speed set 
before. 

 

T4 

Press and hold the button for approximately 2 
seconds to activate automatic shutdown with a 
30' delay (Motor+Lights).  

On. 

 

 

Press and hold for approximately 5 seconds to 
enable/disable the Activated Charcoal Filter 
alarm. 

2 Flashes of the Leds (L1-L2-L3) Filter 
Alarm Enabled.  

1 Flash of the Leds (L1-L2-L3) Filter 
Alarm Disabled. 

 
 

Содержание SHIG910X

Страница 1: ...Instructions Manual SHIG910X ...

Страница 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 10 MAINTENANCE 11 EN ...

Страница 3: ...ks WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure ...

Страница 4: ...EN 4 4 CHARACTERISTICS Dimensions 650mm minimum ...

Страница 5: ...ø 150 120 mm 10 1 Dumper 14 1 1 Air Outlet Connector Extension 15 1 Air Outlet Connector 24 1 Connection box 25 Pipe clamps not included 26 2 Cable clamps 27 1 Finishing plug Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12c 6 Screws 2 9 x 6 5 12e 2 Screws 2 9 x 9 5 12f 2 Screws M4 x 80 12g 4 Screws M6 x 80 12h 4 Screws 5 2 x 70 12q 4 Screws 3 5 x 9 5 21 1 Drilling template 22 8 6 4 mm int...

Страница 6: ...ings with wall thickness of 20 mm drill ø 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet Ducted Version drill according to the diameter of the external air ex haust duct connection Insert two screws of the following type crossing them and ...

Страница 7: ...do not come out of their seats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base is stable even if the frame is sub jected to bending In all cases where the ceiling is not strong enough at the suspension point the installer must provide strengtheni...

Страница 8: ...f the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Otherwise remove the lower chimney and adjust the position by inverting the extension pieces for air outlet connection 14 1 or by cutting the hood body extension piece 14 if any along one of the chases destined to the predetermined extension lengths Replace then the elements as earlier described Fit the di...

Страница 9: ...med on the galva nized diffuser support as shown in fig 2 Position the finishing plug 27 over the housing in the diffuser support fixing it us ing a screw 12e 2 9 x 9 5 and applying the 2 cable clamp elements 26 as indicated in figs 3 and 4 Connect the Controls Connector fig 5 Connect the Lighting Connector fig 6 Store both the Connectors in the Protective box 24 and close it with 2 Screws 12e 2 9...

Страница 10: ...aturation of the activated charcoal filters T2 Turn the suction motor on at speed two On Press and hold for approximately 5 seconds with all the loads turned off Motor and Lights to enable disable the Remote control 2 flashes Remote control Enabled 1 flash Remote control Disabled T3 Turn the suction motor on at speed three On Press and hold the button for 2 seconds to activate intensive speed This...

Страница 11: ...or more frequently if use is particularly intensive Resetting the alarm signal Press button T1 see the paragraph on Use Cleaning the Filters Remove the Filters one at a time pushing them towards the back of the unit and at the same time pulling downward Wash the Filters without bending them and leave them to dry completely before replacing Replace taking care to ensure that the handle faces forwar...

Страница 12: ...ctivated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press button T1 see the paragraph on Use Changing the Filter Remove the Metal grease filters Remove the saturated Activated Charcoal filter as shown in the figure Fit the new Filter hooking it into place Replace the Metal grease filters Lighting LIGHT REPLACEMENT 20 W halogen li...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...436006013_ver2 ...

Отзывы: