EN
1
10
USE
L
T1
T2
T3
T4
L1
L2
L3
L4
Control panel
Button Function
Led
L
Turns the lighting system on and off.
-
Press and hold for approx. 2 seconds to turn the
lighting system on and off at reduced intensity.
-
T1
Turn the suction motor on and off at speed one. On.
Press and hold the button for approximately 2
seconds, with all the loads turned off (Motor
and Lights), to reset the Filters and turn off the
Leds that are lit.
After 100 working hours all the LEDs
(L1-L2-L3-L4) will light up and remain
lit to indicate saturation of the metal
grease filters.
After 200 working hours all the LEDs
(L1-L2-L3-L4) will light up and start to
flash to indicate saturation of the
activated charcoal filters.
T2
Turn the suction motor on at speed two.
On.
Press and hold for approximately 5 seconds,
with all the loads turned off (Motor and Lights),
to enable/disable the Remote control.
2 flashes, Remote control Enabled.
1 flash, Remote control Disabled.
T3
Turn the suction motor on at speed three.
On.
Press and hold the button for 2 seconds to
activate intensive speed. This speed is timed to
run for 10 minutes. At the end of this time the
system will automatically return to the speed set
before.
T4
Press and hold the button for approximately 2
seconds to activate automatic shutdown with a
30' delay (Motor+Lights).
On.
Press and hold for approximately 5 seconds to
enable/disable the Activated Charcoal Filter
alarm.
2 Flashes of the Leds (L1-L2-L3) Filter
Alarm Enabled.
1 Flash of the Leds (L1-L2-L3) Filter
Alarm Disabled.