4.1
Fault clearance checklist
Malfunction
Possible cause
Remedy
Network connection
Power cable not plugged in
Check network connection; connect
another plug if necessary
Power cable defective
Replace power cable
Device does not switch on
Mains fuse
Replace mains fuse.
In the event of fuses blowing
repeatedly you must compulsorily
have the device checked!
Target temperature too low
Increase target temperature
Overtemperature cutout has
triggered
Press in overtemperature cutout.
In the event of repeated triggering
you must compulsorily have the
device checked!
Temperature regulator
Replace temperature regulator
Device is not heating
Heating element
Check heating elements and replace
if necessary
Solid state relay
Replace solid state relay
Target temperature not reached
Motor defective
Replace motor
No material transport
Microswitch defective
Replace microswitch
Toothed damaged
Replace toothed belt
Non-symmetrical material
transport
Tooth belt not transporting
Check toothed belt tension
Loud running noise
Motor defective
Replace motor
Sealing temperature too low
Increase sealing temperature
Sealing seam does not
hold up
Clearance between sealing dies is
too large
Set the sealing die to 0.5mm
Sealing seam distorted or
melted
Sealing temperature too high
Reduce sealing temperature
Содержание SGR10S
Страница 1: ...Betriebsanleitung Operating Instructions Istruzioni per l uso SGR10S...
Страница 20: ...DEUTSCH SGR10S Konformit tserkl rung Kapitel 6 Seite D 19 9 696 035 Version 1 02 6 Konformit tserkl rung...
Страница 39: ...ENGLISH SGR10S Technical data Chapter 5 Version 1 02 9 696 035 Page GB 19 6 Declaration of conformity...
Страница 58: ...ITALIANO SGR10S Dati tecnici Capitolo 5 Versione 1 02 9 696 035 Pagina I 19 6 Dichiarazione di conformit...