background image

 

 

Instructions for the installer

 

 

14

 

6.

 

FINAL OPERATIONS 

Having carried out the above adjustments, reassemble the appliance 
following, backwards, the instructions in paragraph “5.1  Removing the 
hob”. 

 
 
 

6.1

 

Regulation of minimum for natural gas 

Replace the components on the burner and slide 
the knobs on the gas tap pins. 
Light the burner and set it at minimum position. 
Remove the knob and turn the regulation screw 
inside or next to the gas tap pin (depending on 
the model) until you get a suitable minimum 
flame. 
Replace the knob and check burner flame 
stability: (rapidly turning the knob from maximum 
to minimum position, the flame should not go 
out). 

 
 
 

6.2

 

Regulation of minimum for LPG 

To regulate the minimum for LPG, completely tighten (clockwise) the 
screw inside or next to the gas tap pin (depending on the model). 
The diameters of the by-passes for each burner are given in table “5.2 
Regulation for LPG”. 

 
 

 

 

 

After having regulated the device with gas other than the one tested, 
replace the label located on the guard with the one that corresponds to 

the new gas. The label is inside the bag that contains the nozzles 

provided. 

 

 

Содержание SDR597XG5

Страница 1: ... ________________________________________ 16 8 LEANING AND MAINTENANCE ____________________________ 18 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL INSTRUCTIONS FOR THE INSTALLER these are for the qualified technician who must carry out a suitable check of the gas system install the appliance set it functioning and carry o...

Страница 2: ... DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET MUST BE THE SAME TYPE AND MUST CONFORM...

Страница 3: ...DDLE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002 96 EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE THIS GUIDELINE IS THE FRAME OF A EUROPEAN WIDE VALIDITY OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT ...

Страница 4: ... mounted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make sure there is a minimum of 750 mm between the hot plate flames and any shelf that may be installed directly above them Accurately position the gasket provided all around the outer edge of the hole in...

Страница 5: ... on a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily removable to allow access in the event of technical service ...

Страница 6: ... accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 5 mm 2 3 x 1 5 cable keeping in mind that the end to be connected to the hob must have the ground wire yellow green longer by at least 20 mm Use only H05V2V2 F cable or similar which has a maximum temperature of 90 C Any replacement need...

Страница 7: ...n inspected for G20 2H natural gas at a pressure of 20 mbar For use with other types of gases see Section 5 ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228 1 Connection with rigid copper pipe the connection to the gas mains must not provoke stress of any kind on the hob Connection may be made by using biconical adapter D with insertion of gasket C suppl...

Страница 8: ...r intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid overheating or excess humidity produced by cooking and in the case of lengthy use a window should be opened or the speed of any ventilators should be increased 4 3 Discharge of combustion products D...

Страница 9: ...be replaced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the grids the burner caps and the flame caps 2 remove the screws and the nuts A that secure the burner supports 3 remove plates B 4 lift the hob from its seat 5 replace the burner nozzles in accordanc...

Страница 10: ...nturi tube D to regulate the air flow until distance X is reached indicated in the chart in paragraph 5 4 Regulation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent material Burner Rated heating capacity kW LPG G30 G31 28 37 mbar Nozzle diameter 1 100 mm By pass mm 1 100 Reduced flowrate W Flow...

Страница 11: ...lations have been carried out restore the seals with sealing wax or equivalent material Burner Rated heating capacity kW Natural gas G20 20 mbar Nozzle diameter 1 100 mm Reduced flowrate W Auxiliary 1 1 05 73 380 Semi rapid 2 1 65 92 380 Rapid 3 3 1 126 750 internal 5 1 05 73 380 Double crown external 5 3 9 140 1200 5 4 Regulation of primary air Referred to distance X in mm To identify the burners...

Страница 12: ...the model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation of minimum for LPG To regulate the minimum for LPG completely tighten clockwise the screw inside or next to the gas tap pin depending on the model The diameters of the by passes for each burner are gi...

Страница 13: ...rners on hob BURNERS 1 Auxiliary 2 Semi rapid 3 Rapid 4 Double crow 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to be cleaned inside and re greased This must be done by a qualified technician ...

Страница 14: ...n the low point flame symbol until the burner is ignited Concerning models with valves push the knob for approximately 2 seconds in order to keep the flame burning and to activate the safety device The burner might go off when the knob is released In this case repeat the aforesaid operation keeping the knob pressed for more than 2 seconds Double crown burners comprise an auxiliary and a rapid burn...

Страница 15: ...s Burner Ø min and max in cm 1 Auxiliary 12 14 2 Semi rapid 16 20 3 Rapid 22 26 4 Double crown 12 34 For burner reference numbers see page 15 7 4 Using a griddle plate A few precautions are necessary if you wish to use a griddle plate leave a gap of at least 160 mm between the edge of the griddle plate and the side wall if one of the burners close to the wooden rear wall is of triple flame type le...

Страница 16: ...e the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroughly and dry with a soft cloth or deerskin 8 1 2 Food stains or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products and remove spots or...

Страница 17: ...al products for appliance cleaning and care 8 2 1 Ignition plugs and safety devices For good functioning of the lighting ignition plugs and the safety devices keep them very clean Check frequently and clean with a damp cloth when necessary 8 2 2 The electric element After use to make sure that the surfaces are clean and long lasting the electric element must be treated with specific cleaning produ...

Отзывы: