10. USING THE HOME GARDEN

At first switch-on, the circuit board automatically presets for the use of program 

. The 

 symbol

flashes to indicate that the time must be set on the control circuit board. For instructions on this
procedure, see point "9.6 Clock display/setting key".

WARNING:

 THE HOME GARDEN CAN ONLY BE OPERATED WITH THE REMOTE CONTROL.

THE CONTROL PANEL ON THE FRONT OF THE APPLIANCE IS PURELY AESTHETIC AND DOES
NOT OPERATE THE HOME GARDEN.

10.1 Removing and placing the pots in the Home Garden

To remove the pots from the appliance, proceed as follows:
Lift the appliance’s two side panels by their handles. The panels are mounted on sliding supports and
should be lifted gently to their maximum extension by simply pulling upwards. At this point, with both side
panels raised, the two sliding trays on which the pots are located can be pulled out. Take care not to exert
excessive force: the end stop which prevents them from falling may be damaged by this. Once the two
sliding trays are fully extended, the pots are available for use.
To refit them inside the Home Garden, simply repeat the same operations in reverse order.

WARNING:

 DIFFERENT POTS FROM THOSE SUPPLIED WITH THE HOME GARDEN MAY NOT BE

SUITABLE FOR GROWING YOUR PLANTS IN THE APPLIANCE

WARNING:

 THE HOME GARDEN IS CONSTRUCTED LARGELY OF GLASS. PROCEED GENTLY

AND WITH CARE WHEN HANDLING. 

10.2 Automatic regulation of the internal micro-climate

The Home Garden is equipped with three sensors (humidity, light and temperature) which allow its
circuitry to control its environmental variables in accordance with the selected program.
There are three programs for the various types of plant you may wish to grow in the appliance.
The following table explains the types of plants which each program is intended to work with.

PROGRAM

PLANTS

OPERATING PARAMETERS

1

Green plants (decorative,
indoors), indoors bonsai,
cuttings and orchids.

- High 

humidity.

-  Automatic heating when the external tempera-

ture is lower than 18°C - 64°F

-  In case of insufficient external light, the appli-

ance’s lights stay on from 7:00 to 20:00.

-  Low ventilation frequency.

2

Succulents. (eg. Cacti)

- Low 

humidity.

- Automatic heating when the external

temperature is lower than 20°C - 68°F

-  In case of insufficient external light, the appli-

ance’s lights stay on from 7:00 to 21:00.

-  High ventilation frequency.

3

Flowering plants
and seedlings.

- Moderate 

humidity.

-  Automatic heating when the external tempera-

ture is lower than 18°C - 64°F

-  In case of insufficient external light, the appli-

ance’s lights stay on from 7:00 to 20:00.

-  Average ventilation frequency.

CHECK THAT THE SELECTED PROGRAM IS SUITABLE FOR THE PLANTS YOU INTEND TO
GROW, WHICH MUST OBVIOUSLY ALL BE OF THE SAME TYPE.
IF, FOR EXAMPLE, YOU DECIDE TO REPLACE YOUR SUCCULENTS WITH GREEN PLANTS, YOU
MUST CHANGE FROM PROGRAM 2 TO PROGRAM 1 AS DESCRIBED ABOVE.

Содержание SDP20UL

Страница 1: ...8 8 Internal light ON symbol 16 8 9 Cuttings function on symbol 16 8 10 Remote control sensor 16 9 THE REMOTE CONTROL 17 9 1 Red led 17 9 2 Standby key 17 9 3 Cuttings function on key 18 9 4 Humidifie...

Страница 2: ...ld lose your life or be seriously injured if you do not immediately follow the instructions WARNING means you could lose your life or be seriously injured if the instructions are not followed CAUTION...

Страница 3: ...arden stand HOUSEHOLD HOME APPLIANCE FOR HOUSEHOLD USE ONLY THIS FURNISHING HAS NOT BEEN EVALUATED FOR FLAMMABILITY OR CIGARETTE IGNITION RESISTANCE DO NOT ATTEMPT TO MOVE THE DEVICE BY PULLING ON THE...

Страница 4: ...VOID ACCIDENTAL COLLISIONS IT SHOULD BE PLACED ON A SUITABLE AND STABLE SURFACE TO AVOID IT FALLING ACCIDENTALLY SAVE THESE INSTRUCTIONS OUR HOME GARDENS ARE PACKAGED ONLY WITH NON POLLUTANT ENVIRONME...

Страница 5: ...ECLINES ALL LIABILITY FOR USES OTHER THAN THOSE STATED ABOVE NEVER LEAVE PACKAGING RESIDUES UNATTENDED IN THE HOME SEPARATE WASTE PACKAGING MATERIALS BY TYPE AND CONSIGN THEM TO THE NEAREST SEPARATE D...

Страница 6: ...REGULARLY IRRIGATE MANURE TRIM THEM AND CLEAN THEIR LEAVES AND TAKE ALL THE FURTHER MEASURES NECESSARY FOR THEIR CARE THESE MEASURES ARE NOT RENDERED UNNECESSARY BY THE USE OF OUR PRODUCT BUT ARE IND...

Страница 7: ...all dimensions 5 1 1 Home Garden s overall dimensions The drawing below shows the Home Garden s maximum overall dimensions with the glass panels and trays open Fig 1 5 1 2 Pot overall dimensions The d...

Страница 8: ...PORTING SURFACE AS THIS MAY BLOCK THE AIR INTAKES BENEATH IT The Home Garden may be placed on a pedestal optional available from your service center Completely unscrew the feet and fit the studs into...

Страница 9: ...ube in its central seat as shown by movement C in Figure 5 5 4 Electrical connection Connect the appliance s power supply lead to a mains socket installed in accordance with electrical safety regulati...

Страница 10: ...al Filling The Home Garden s tank is empty when purchased It must be filled for the appliance to operate For filling instructions see 11 1 Filling the tank on page 22 IT IS ADVISABLE TO FILL THE TANK...

Страница 11: ...ures required to start up the Home Garden when using it for the first time 1 switch on the Home Garden by pressing the button on the remote control see Section 9 2 Standby key 2 select the program dep...

Страница 12: ...our appliance 14 7 GETTING TO KNOW YOUR APPLIANCE FIG 7 HUMIDIFIER WATER TANK CONTROL PANEL SLIDING TRAYS PLANT POTS VAPOR DELIVERY TUBE LED LAMP HUMIDITY AND INTERNAL TEMPERATURE SENSOR TANK FILLER C...

Страница 13: ...2 Internal clock setting display symbol This symbol indicates that the key on the remote control has been pressed to show the current time on the displays For instructions for setting the time see 9 6...

Страница 14: ...ontrol has not been used for ten minutes consecutively the Home Garden locks its current setting and commands are not accepted from the remote control This is a precaution against misuse accidental or...

Страница 15: ...run a check of the displays and all control panel leds will light up Once this check has terminated the system will ask you to select one of the 3 pre set programs or the manual setting program For s...

Страница 16: ...CTION ARE ON DO NOT TOUCH THESE PANELS WITH YOUR BARE HANDS BEFORE ALLOWING THEM SUFFICIENT TIME TO COOL DOWN 9 4 Humidifier key This key manually delivers a few jets of water vapor into the Home Gard...

Страница 17: ...n the selected program During normal operation and when the Home Garden is not locked press the key once to display the time For the preset programs see 10 2 Automatic regulation of the internal micro...

Страница 18: ...OF GLASS PROCEED GENTLY AND WITH CARE WHEN HANDLING 10 2 Automatic regulation of the internal micro climate The Home Garden is equipped with three sensors humidity light and temperature which allow i...

Страница 19: ...rden has a manual program in which the operating parameters temperature and humidity can be modified To do this select program as described in point 10 3 Selecting the program To modify the preset pro...

Страница 20: ...s WHEN THE SYMBOL STARTS FLASHING SOME AMOUNT OF WATER IS STILL LEFT IN THE TANK BUT IT CANNOT BE USED Extract the sliding trays and pots as described in paragraph 10 1 Removing and placing the pots i...

Страница 21: ...eaning the ultrasound vaporizer If it is necessary to clean the internal vaporizer for example because vapor is not delivered even after you have thoroughly cleaned the hose contact your nearest Autho...

Страница 22: ...as been exceeded The tank has been filled beyond the maximum level Wait a few minutes and try again Empty the tank with a syringe or similar device as described in paragraph 11 1 Filling the tank The...

Отзывы: