Important Safety Instruction

3

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS – Your Safety And the Safety of Others Are Very Important.
We have provided many important safety messages throughout this manual and on your appliance.
Read all instructions before using your appliance and always obey all safety messages.

RECOGNIZE SAFETY INFORMATION
This is a safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and
others.

UNDERSTAND SIGNAL WORDS
A signal word – DANGER, WARNING, or CAUTION – is used with the safety-alert symbol. DANGER
identifies the most serious hazards. It means you can be killed or seriously injured if you do not
immediately follow instructions. WARNING means you can be killed or seriously injured if you do not
follow instructions. CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury. 

All safety messages will inform you as to potential hazards, inform you on how to reduce the risk of
injury and as to what can occur if the instructions are not followed.

IMPORTANT: Observe all government codes and ordinances.

WARNING: For your safety, the information in this manual must be followed to minimize the risk
of fire or explosion, or to prevent property damage, personal injury or death.

-  This conversion kit must be installed by a qualified service agency in accordance with the

manufacturer's instructions and all applicable codes and requirements of the authority
having jurisdiction.

-  The qualified service agency is responsible for the proper installation of this kit.

-  The installation shall not be considered to be correct and completed until the operation of the

converted appliance is checked as specified in the manufacturer's instructions supplied with
this kit. 

  WARNING

FIRE HAZARD

Securely tighten all gas connections. If connected to LP, have a qualified
person ensure that the gas pressure does not exceed 14" water column.
Examples of a qualified person include licensed heating personnel,
authorized gas company personnel, and authorized service personnel. 

FAILURE TO DO SO CAN RESULT IN DEATH, EXPLOSION, OR FIRE. 

Содержание PU 64-LP

Страница 1: ...rds inform you on how to reduce the risk of injury and as to what can occur if the instructions are not followed IMPORTANT Observe all government codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death This conversion kit must be installed by a qualified service age...

Страница 2: ...regulator The regulator must be checked at a minimum water column of 1 inch 2 5 cm above the set pressure The inlet pressure to the regulator should be as follows for operation and checking the regulator setting NATURAL GAS Set pressure at 6 15 2 cm Supply pressure of 7 14 17 8 cm to 35 5 cm maximum LP GAS Minimum pressure of 10 25 4 cm Supply pressure of 14 35 5 cm The cooktop must be isolated fr...

Страница 3: ...rd remove the grids 2 lifting up one of the two horizontal spokes remove the burner caps 3 and flame caps 4 with wrench A available from authorized service centers open the bayonet clamps on the burner rings by levering on guides B After having removed all of the above described components lift the surface to gain access to the burners and gas taps ...

Страница 4: ... Front Left 4000 0 60 1500 0 40 Central A 12000 1 30 4000 Central A 11500 0 87 4000 0 58 B 0 71 B 0 48 Rear right 5200 0 95 1800 Rear right 5400 0 67 1800 0 40 Rear left 7200 1 13 3000 Front Left 7300 0 78 3000 0 50 PU 75 Natural gas PU 75 LP Qt Injector Qr Qt Injector Qr Qr BTU Ø mm BTU BTU Ø mm BTU BTU Central right A 12000 1 30 4000 Central right A 11500 0 87 4000 0 58 B 0 71 B 0 48 Central lef...

Страница 5: ... 10 mm Front left 3 16 4 5 mm Front left 1 10 2 5 mm Rear right 1 8 3 mm Rear right 1 10 2 5 mm Rear left 5 32 3 5 mm Rear left 1 8 3 mm PU 75 Natural gas PU 75 LP Air Shutter Air Shutter Front right 2 10 5 mm Front right 3 8 10 mm Front left 2 10 5 mm Front left 3 8 10 mm Central A 1 2 13 mm Central A 9 16 14 mm B 1 2 13 m B 9 16 14 mm Rear right 3 16 4 5 mm Rear right 1 10 2 5 mm Rear left 5 32 ...

Страница 6: ...o the following instructions Use a brush and liquid detergent to test all gas connections for leaks Bubbles around connections indicate a leak If a leak appears shut off gas valve controls and adjust connections Then check the connections again NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAMES Remove all of the detergent solution from the cooktop Electronic Ignition System initial lighting Coo...

Страница 7: ...imary air intake is closed too far C the flame is blue clear and stable and does not blow away from or wrap around the burner the air is set correctly 12 Check flame at the maximum flame position for a blue color It should be clean and soft in character No blowing or lifting of flame should occur Occasional orange flashes are normal and reflect different elements in the air or gas 13 Completely fi...