Installation
55
EN
The nozzles not provided are available at Authorised Service Centres.
7
LPG G30/31 - 37 mbar
AUX
SR
RR
RR*
R
UR
UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10
1.70
2.60
2.60
3.10
3.50
1.00
3.20
Nozzle diameter (1/100 mm)
48
60
73
73
80
82
45
80
Reduced flow rate (W)
450
550
750
750
1100
1600
450
1400
Primary air (mm)
1.5
1.5
1.5
1.5
10
2.5
6
12
Rated flow rate G30 (g/h)
80
124
189
189
225
254
73
233
Rated flow rate G31 (g/h)
79
121
186
186
221
250
71
229
8
LPG G30/31 - 50 mbar
AUX
SR
RR
RR*
R
UR
UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10
1.70
2.60
2.60
3.10
3.50
1.10
3.10
Nozzle diameter (1/100 mm)
42
54
67
67
73
76
42
73
Reduced flow rate (W)
400
500
800
800
1000
1600
400
1400
Primary air (mm)
1
0.5
1
2
2
1.5
2
12
Rated flow rate G30 (g/h)
80
124
189
189
225
254
80
225
Rated flow rate G31 (g/h)
79
121
186
186
221
250
79
221
9
Town gas G110 – 8 mbar
AUX
SR
RR
RR*
R
UR
UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10
1.70
2.60
2.60
3.10
3.50
1.00
3.20
Nozzle diameter (1/100 mm)
132
165
210
210
250
270
132
250
Reduced flow rate (W)
400
500
750
750
900
1400
400
1200
Primary air (mm)
0.5
0.5
0.5
1
0.5
1
1
2
10
Town gas G120 – 8 mbar
AUX
SR
RR
RR*
R
UR
UR2 int. UR2 ext.
Rated heating capacity (kW)
1.10
1.70
2.60
2.60
3.00
3.50
1.00
3.20
Nozzle diameter (1/100 mm)
126
165
200
200
230
250
126
230
Reduced flow rate (W)
400
500
750
750
900
1400
400
1200
Primary air (mm)
0.5
0.5
0.5
1
1
1.5
1
2.5