Installation
52
Replacing nozzles
1. Unscrew screw
A
and push air regulator
B
as far as it will go.
2. Use a spanner to remove the nozzles
C
and install the new ones for the required
gas supply, following the indications
given in the relevant table (see “Gas
types and Countries”).
3. Adjust the air flow by moving the air
regulator
B
to obtain the distance
D
given in the relevant table (see “Gas
types and Countries”).
4. After adjusting each burner, reassemble
the appliance correctly.
Adjusting the minimum setting for natural
or city gas
Light the burner and turn it to the minimum
position. Extract the gas tap knob and turn
the adjustment screw next to the tap rod
(depending on the model) until the correct
minimum flame is achieved.
Refit the knob and verify that the burner
flame is stable. Turn the knob rapidly from
the maximum to the minimum setting: the
flame should not go out. Repeat the
operation on all gas taps.
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
tap rod clockwise all the way.
The nozzle tightening torque must
be no more than 3 Nm.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new gas.
The label is inserted inside the
nozzle pack (where present).
Содержание P64XGHUE
Страница 8: ...Description 38 2 Description 2 1 General Description 60 cm 72 cm...
Страница 28: ......