Instructions for the installer
EN
38
U.L.P.G.
Can be connected to the inlet fitting directly.
The pressure must be checked to ensure it is
operating at 2.75kPa. A separate test point fitting must
be installed between the piping & the appliance for the
pressure to be checked to ensure it is operating at
2.75kPa.
Installation with the flexible hose must be carried out so that the length of the
piping does not exceed 1.2 metres fully extended; make sure that the hoses do
not come into contact with moving parts and that they are not crushed in any way.
11.4
Connection to liquid gas
Use a pressure regulator and make the connection on the gas cylinder following
the guidelines set out in the regulations in force.
Make sure that the supply pressure complies with the values indicated in the
paragraph “3.2 Burner and nozzle characteristics table”.
11.5
Ventilation in the room containing the appliance
The room containing the appliance should have a permanent air supply in
accordance with the standards in force. The room where the appliance is
installed must have enough air flow needed for the regular combustion of
gas and the necessary air change in the room itself. The hob shall be
installed in rooms with natural ventilation, as required by Standards
regulations AS/NZS5601.
11.6
Extraction of the combustion products
The combustion products can be extracted by means of hoods connected to a
natural draught chimney whose efficiency is certain or via forced extraction. An
efficient extraction system requires precision planning by a specialist qualified in
this area and must comply with the positions and distances indicated by the
applicable standards. When the job is complete, the installer must issue a
certificate of conformity.
Содержание Oven
Страница 43: ......
Страница 44: ...914774767 A ...