Cleaning metal grease filters

The metal grease filters can be cleaned in hot detergent 

solution or washed in the dishwasher. They should be 

cleaned every 2 months use, or more frequently if use 

is particularly heavy. 

• 

Remove the filter, pushing the lever towards the back 

of the unit and at the same time pulling downward.

• 

Wash  the  filter  without  bending  it,  leave  it  to  dry 

thoroughly before replacing (if the surface of the filter 

changes color over time, this will have absolutely no 

effect on its efficiency).

• 

Replace, taking care to ensure that the handle faces 

forward.

• 

Cleaning  in  dishwasher  may  dull  the  finish  of  the 

metal grease filter.

• 

No water can be present in filters before installing 

back in hood.

Cleaning Exterior surfaces

Cleaning Exterior surfaces: 

Please note, abrasives and scouring agents can scratch 

range hood finishes and should not be used to clean 

finished surfaces.

Stainless Steel finish cleaning instructions:

Clean exterior surfaces with a commercially available 

stainless steel cleaner.

Painted Gray finish cleaning instructions:

Clean exterior surfaces with hot soapy water.

Replacing Activated Charcoal Filter

The Activated Charcoal Filters are not washable 

and cannot be regenerated, and must be replaced 

approximately every 4 months of operation, or more 

frequently with heavy usage.

•  Remove the grease filters.

•   Remove the saturated carbon filter.

•  Fit the new filter by hooking it into its seating.

•  Replace the grease filters.

Caution:

 When used in recirculation mode, to 

Reduce the Risk of Fire and Shock use only 

conversion kit Model KITFC142.

Содержание KSEG24XU

Страница 1: ...KSEG24XU KSEG30XU Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien Instrucciones de instalaci n Informaci n de uso y cuidado...

Страница 2: ...with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING...

Страница 3: ...equirements may result in a fire WARNING VENTING REQUIREMENTS Determine which venting method is best for your application Ductwork can extend either through the wall or the roof The length of the duct...

Страница 4: ...follow electrical requirements may result in a fire WARNING State of California Proposition 65 Warning US only WARNING This product contains chemicals known to the State of California to cause cancer...

Страница 5: ...5 RANGE HOOD DIMENSIONS 21 47 RANGE HOOD DIMENSIONS 28 47...

Страница 6: ...IC INSTALLATION HEIGHT REQUIREMENTS MIN 30 OVER GAS THE HOOD IS NOT DESIGNED FOR USE OVER PRO STYLE COOKING SURFACES INSTALLATIONS OVER PRO STYLE COOKING SURFACES WILL COMPLETELY VOID THE WARRANTY OF...

Страница 7: ...Filters Blower 10 1 Damper 5 Ref Qty Installation Components 12a 10 Screws for hood installation 12b 4 Screws 1 8 x1 2 for Cover installation Qty Documentation 1 Instruction Manual H I H I H I 12b 10...

Страница 8: ...8 Available Accessories Parts needed 5 Round Metal ductwork Activated Charcoal Filter sku KITFC142 Two men required for installation Wear work gloves for safety...

Страница 9: ...5 Non Ducted Recirculation Ducted Venting Installation Remove the metal packaging support piece from the top of the hood before installation Caution If an elbow is required do it as far away from the...

Страница 10: ...10 INSTALL THE RANGE HOOD 1 2 Remove grease filters and set aside Remove the bottom of the Range Hood by pulling forward as shown...

Страница 11: ...s and 30 for gas ranges Create an opening in the bottom of the Cabinet as shown Attention The cabinet must be accessible so that you can access the hood cable and plug in the future after installing t...

Страница 12: ...he side supports snap into place Lock in position by tightening the screws Vf from underneath the hood Fasten using the 10 screws 12a provided Min 9 16 Max 1 3 16 Vf Attention KSEG24XU uses 8 screws K...

Страница 13: ...13 Replace the bottom of the Range Hood by 4 screws 12b as shown Place the grease filters in the hood 6 7 12b...

Страница 14: ...Connect the 5 metal ductwork to the Roof or Wall Cap and then attach ductwork Required Activated Charcoal Filter Accessory sku KITFC142 8 For Non Ducted Recirculation venting route the ductwork to a l...

Страница 15: ...a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock C...

Страница 16: ...16 10 For Non Ducted Recirculation Option The charcoal filters must be inserted behind the grease filters as indicated Required Activated Charcoal Filter Accessory sku KITFC142...

Страница 17: ...tes after cooking is complete to clear all smoke and odors from the kitchen Button Function LED indicator light L Light On Off Button On Off switch for the lights Press the button to turn the light ON...

Страница 18: ...fore installing back in hood Cleaning Exterior surfaces Cleaning Exterior surfaces Pleasenote abrasivesandscouringagentscanscratch range hood finishes and should not be used to clean finished surfaces...

Страница 19: ...tom of the Range Hood by 4 screws 12b as shown Replace the lamp with a new one of the same type Replace the bottom of the Range Hood by 4 screws 12b Replace the grease filters E12 self ballasted led l...

Страница 20: ...ings ca gov AVERTISSEMENT DE LA PROPOSITION 65 DE L TAT DE CALIFORNIE Cancer reproducteur et www P65Warnings ca gov Troubles de l appareil ADVERTENCIA DE LA PROPUESTA 65 DEL ESTADO DE CALIFORNIA Cance...

Отзывы: