Fixing the frame 

•  Loosen the two screws  fastening the lower chimney and re-

move this from the lower frame. 

•  Loosen the two screws  fastening the upper  chimney and re-

move this from the upper frame. 

If you wish to adjust the height of the frame, proceed as follows: 
•  Unfasten the metric screws joining the two columns, located at 

the sides of the frame.  

•  Adjust the frame to the height required, then refit all the screws 

removed as above. 

•  Insert the upper chimney stack from above, and leave it run-

ning free on the frame. 

•  Lift up the frame, fit  the frame slots onto the screws up to the 

slot end positions. 

•  Tighten the two screws and fasten the other two screws pro-

vided with the hood. 

Before tightening the screws completely it is possible to adjust 
the frame by turning it. Make sure that the screws do not come 
out of their seats in the slotted holes. 
•  The frame mountings must be secure to withstand the weight 

of the hood and any stresses caused by the occasional side 
thrust applied to the device.  

  On completion, check that the base is stable, even if the frame 

is subjected to bending.  

•  In all cases where the ceiling is not strong enough at the sus-

pension point, the installer must provide strengthening using 
suitable plates and backing pieces anchored to the structurally 
sound parts. 

2

2

1

1

Connections 

DUCTED VERSION AIR EXHAUST SYSTEM 

When installing the ducted version, connect the hood to the 
chimney using either a flexible or rigid pipe ø 150 or 120mm, the 
choice of which is left to the installer. 

To install a ø 150 pipe 
•  To install the dumper 10
•  Fix the pipe in position using sufficient pipe clamps (not sup-

plied). 

To install a ø 120 pipe 
•  To install a ø 120 mm air exhaust connection, insert the re-

ducer flange 9 on the dumper 10.

•  Fix the pipe in position using sufficient pipe clamps (not sup-

plied). 

•  Remove any activated charcoal filters. 

ø 120

ø 150

10

10

9

Содержание KI120X

Страница 1: ...Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es KI120X...

Страница 2: ...E CONSEILS ET SUGGESTIONS 24 CARACTERISTIQUES 25 INSTALLATION 27 UTILISATION 31 ENTRETIEN 32 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 34 CHARAKTERISTIKEN 35 MONTAGE 37 BEDIENUNG 41 WARTUNG 42 INHO...

Страница 3: ...3 3 NDICE CONSELHOS E SUGEST ES 64 CARACTER STICAS 65 INSTALA O 67 UTILIZA O 71 MANUTEN O 72 PT...

Страница 4: ...r than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it d...

Страница 5: ...EN 1 5 15 CHARACTERISTICS Dimensions Min 500mm Min 650mm 676 60 898 1198 max 1050 min 870 700 290 350 150 90 310 135...

Страница 6: ...l 14 1 Hood Body Air Outlet Extension Piece consisting of two Half Shells Optional 14 1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection 24 1 Junction box 25 Pipe clamps not included Ref Q...

Страница 7: ...ceilings with wall thickness of 20 mm drill 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill 7 mm For the power s...

Страница 8: ...ats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the...

Страница 9: ...of the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Otherwise remove the lower chimney and adjust the position by inverting the extension pieces for air outle...

Страница 10: ...e is correctly inserted in the socket placed on the side of the fan Connect the control connector Cmd Connect the lights connector Lux Place the connectors in the junction box 24 and close it using th...

Страница 11: ...cooking fumes it is de activated by pressing any one of the Speed buttons T1 T2 T3 It cannot be activated if the Delay function is in use If the filter saturation alarm is on this resets it On Flashi...

Страница 12: ...r more frequently if use is particularly intensive Resetting the alarm signal Press any of the buttons except the Light button Cleaning the Filters Remove the Filters one at a time supporting them wit...

Страница 13: ...nce Activated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press any of the buttons except the Light button Changing the Filter Remov...

Отзывы: