EN
2
3
23
Activated Charcoal Filter (Recirculation Version)
• This cannot be washed or regenerated, and must be changed when all the command LEDs
start to flash, or at least once every 4 months.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at
a later date.
• Press and hold the Delay button (T4) on the keypad for 5 seconds and the following will be dis-
played:
• Leds (L1-L2-L3) flash twice – Activated Charcoal Filter saturation alarm ACTIVATED.
• Leds (L1-L2-L3) flash once – Activated Charcoal Filter saturation alarm DEACTI-
VATED.
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Press any of the buttons except the Light button.
Changing the Filter
• Remove the Metal grease filters.
• Remove the saturated Activated Charcoal filter, as shown in
the figure.
• Fit the new Filter, hooking it into place.
• Replace the Metal grease filters.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Refit the Support, fixing it in place with the two screws re-
moved as above.