Installation
46
The appliance can work in the following
modes:
•
220-240 V 1N
~
use a
3 x 1,5 mm² three-core
cable.
Fixed connection
Fit the power line with an all-pole circuit
breaker with a contact separation distance
sufficient to provide complete disconnection
in category III overvoltage conditions,
pursuant to installation regulations. The
disconnection incorporated in the fixed
wiring must be compliant to AS/NZS 3000
regulations.
Connection with plug and socket
Make sure that the plug and socket are of
the same type.
Avoid use of adapters and shunts as these
could cause overheating and a risk of
burns.
5.6 For the installer
• The plug must remain accessible after the
installation is complete. Do not kink or
trap the mains connection cable.
• The appliance must be fitted according
to the installation diagrams.
• Do not attempt to turn or stress the
threaded elbow on the manifold. You risk
damage to this part of the appliance
which may void the manufacturer’s
warranty.
• Before leaving check all connections for
gas leaks with soap and water. DO
NOT use a naked flame for detecting
leaks.
• Ignite all burners individually and
concurrently to ensure correct operation
of the gas valves, burner and ignition.
• Turn the gas knobs to the low position
and observe stability of the flame for
each burner individually and all together.
• In case the appliance fails to operate
correctly after all checks have been
carried out, refer to the Authorised
Assistance Centre in your area.
• When satisfied with the appliance,
please instruct the user on the correct
method of operation.
The values indicated above refer
to the cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).