Smeg Freestanding Gas Range C6GGXU Скачать руководство пользователя страница 3

Conversion Kit

5

1)

Check that the main gas supply line to the range is shut off and that the
power supply cord is disconnected. 

2)

Remove access cap “A” by using a screwdriver or a coin, turning the access cap counterclockwise.
The gas pressure regulator has two settings which are indicated on two sides of the cap. Turn the cap
and reinstall it in the regulator with "LP" visible from the outside of the regulator. 

Incoming line pressure upstream
from the regulator must be 1” (2.5
cm) W.C.P. higher than the manifold
pressure in order to check the
regulator. Incoming line pressure to
the regulator should be as follows for
operation and checking the regulator
setting: - NATURAL GAS: 
Set pressure to 4” W.C.P. Incoming

line pressure of 3 

1

/

2

” - 10 

1

/

2

” W.C.P

maximum; - LP GAS: Set pressure
to 11” W.C.P. Incoming line pressure
8”- 13” W.C.P. maximum.

The range must be isolated from the gas supply piping system by turning off the respective manual shut-
off valve during any pressure testing of the gas supply piping system at test pressures equal to or
greater than 1/2 psig (3.5 kPa).

Replacing the rangetop's burners nozzles

 (This operation does not require primary air regulation.)

3)

1 Remove the grates and all the burner caps and

heads;

2 Unscrew the burner nozzles with a 7 mm socket

wrench;

3 Replace the nozzles according to the type of gas to

be used and the description in paragraph 3.2
“Burner and nozzle characteristics table”.

Put the burners back in their correct position.

Содержание Freestanding Gas Range C6GGXU

Страница 1: ...or gas supplier READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important We have provided many important safety messages throughout this manual and on the appliance Re...

Страница 2: ...s instructions and all applicable codes and requirements of the authority having jurisdiction The qualified service agency is responsible for the proper installation of this kit Installation shall no...

Страница 3: ...nd checking the regulator setting NATURAL GAS Set pressure to 4 W C P Incoming line pressure of 3 1 2 10 1 2 W C P maximum LP GAS Set pressure to 11 W C P Incoming line pressure 8 13 W C P maximum The...

Страница 4: ...crew 3 4 5 Remove the burner from its place by sliding it out and moving it to the side Make sure not to damage the thermocouple or the spark electrode during this operation 6 Using a 7mm socket wrenc...

Страница 5: ...s fastening screw 2 Remove the burner by sliding it from its place and reposition it as shown in the picture Make sure not to damage the thermocouples and the spark electrode 1 2 3 Using a 13mm socke...

Страница 6: ...12000 1 17 n 2 4000 Inner 3000 0 85 1200 Oven 11200 1 60 3400 Broiler 10500 1 55 4100 LP Qt Injector Qr by pass BTU mm BTU mm Front Right 6200 0 72 1500 0 39 Front Left 6200 0 72 1500 0 39 Rear Left...

Страница 7: ...Broiler 19000 2 15 5800 LP Qt Injector Qr by pass BTU mm BTU mm Front Right 6200 0 72 1500 0 39 Front Center 3400 0 54 1200 0 33 Front Left 6200 0 72 1500 0 39 Rear Left 3400 0 54 1200 0 33 Rear cente...

Страница 8: ...screw next to the gas tap pin until you obtain a suitable minimum flame Replace the knob and check flame stability by rapidly turning the knob from maximum to minimum The flame should not go out 8 Ch...

Отзывы: