CW
620/630
21
6.15
Service
setting
(for
After
‐
Sales
Service
only)
See
information
on
Smegtech
6.16
Starting
the
peristaltic
pumps
–
rapid
filling
of
detergent
and
rinse
aid
delivery
circuit.
Perform
after
the
parameter
modification
procedure
explained
in
the
previous
point.
With
the
dishwasher
powered
up,
access
“programming
mode”
by
pressing
the
on/off
button
for
a
few
seconds;
at
the
“beep”,
release
the
button
and
press
it
again
quickly
within
0.5
seconds
.
The
peristaltic
pumps
continue
to
operate
until
the
same
button
is
pressed
again.
The
rinse
aid
and
detergent
symbol
lights
remain
on
as
long
as
the
pumps
are
on;
bear
in
mind
that
the
rinse
aid
peristaltic
pump
fills
the
circuit
in
about
7
minutes,
while
for
the
detergent
it
only
takes
2
minutes.