Installation
46
Lubrication of gas cocks
Over time the gas cocks may become
difficult to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Burner and nozzle characteristics table
Overall dimensions
Location of gas and electrical connection
points.
E
Gas connection
G
Electrical connection
The greasing of the gas cocks
should be performed by
authorised persons.
1 ULPG 2.75 kPa
AUX
SR
R
UR2
Nominal gas consumption (MJ/h)
4.0
6.5
10.8
15.2
Injector (1/100 mm)
54
68
88
105
2 NG 1.0 kPA
AUX
SR
R
UR2
Nominal gas consumption (MJ/h)
4.5
7.5
12
15.2
Injector (1/100 mm)
90
120
155
175
A
51 mm
B
624 mm
C
126 mm
D
28 mm