Instructions for the installer
72
If the appliance is connected to the power supply network by means of a fixed
connection, install a multipolar cut-out device on the power supply line, in
accordance with the installation rules, located near the appliance and in an
easily reachable position.
If a plug and socket connection is being used, make sure that the plug and
socket are compatible. Avoid use of adapters and shunts as these could cause
overheating and a risk of burns.
Operation at 220-240 V~:
use a H05V2V2-F type
three-core cable (3 x 1.5 mm
2
).
The end to be connected to the appliance must
have an earth wire (yellow-green) at least 20 mm longer than the others.
WARNING: The values indicated above refer to the cross-section of the internal
conductor.
13.2 Extraction of the combustion products
The combustion products must be extracted by means of hoods connected to a
natural draught chimney whose efficiency is certain or via forced extraction. An
efficient extraction system requires precision planning by a specialist qualified in
this area and must comply with the positions and distances indicated by the
applicable standards. When the job is complete, the installer must issue a
certificate of conformity.
13.3 Room ventilation
The room containing the appliance should have a permanent air supply in
accordance with the standards in force. The room where the appliance is
installed must have enough air flow for the regular combustion of gas and for the
air exchange needed in the room itself. The air vents, protected by grills, must
be suitably dimensioned in compliance with the current regulations and
positioned so that no part of them is obstructed.
The cooker must be kept adequately ventilated in order to eliminate the heat and
humidity produced by cooking: in particular, after prolonged use, you are
recommended to open a window or to increase the speed of any fans.