Instructions for the installer
41
15. ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any operations requiring access to powered parts, switch off the power supply to the
appliance.
The cooker hob is preset for
natural gas G20
(2H) at a pressure of 20 mbar. In the case of operation
with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas
taps. To change the nozzles, proceed as described below.
15.1 Replacement of nozzles on the hob
This operation does not require the primary air to be adjusted.
7 Extract the grids and remove all the caps and flame-spreader crowns;
8 Unscrew the burner nozzles with a 7 mm socket wrench;
9 Replace the nozzles according to the type of gas to be used and the description in paragraph "15.2
Burner and nozzle characteristics table";
10 Replace the burners in the correct position.