Installation
36
Nozzles which are not provided are available at Authorised Service Centres.
8 LPG G30/31
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.75
2.9
4.0
Nozzle diameter (1/100 mm)
50
65
85
102
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced capacity (W)
400
500
800
1600
Rated capacity G30 (g/h)
73
127
211
291
Rated capacity G31 (g/h)
71
125
207
286
9 LPG G30/31
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
2.9
4.0
Nozzle diameter (1/100 mm)
50
65
81
94
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced capacity (W)
450
550
800
1600
Rated capacity G30 (g/h)
73
131
211
291
Rated capacity G31 (g/h)
71
129
207
286
10 LPG G30/31
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
2.9
3.8
Nozzle diameter (1/100 mm)
43
58
74
77
Pre-chamber (printed on nozzle)
(H2)
(M)
(Z)
(F4)
Reduced capacity (W)
400
500
800
1600
Rated capacity G30 (g/h)
73
131
211
276
Rated capacity G31 (g/h)
71
129
207
271
11
City Gas G110
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
2.8
3.8
Nozzle diameter (1/100 mm)
145
185
260
340
Pre-chamber (printed on nozzle)
/8
/2
/3
/13
Reduced capacity (W)
400
500
800
1400
12
City Gas G120
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
2.9
3.8
Nozzle diameter (1/100 mm)
145
185
260
315
Pre-chamber (printed on nozzle)
/8
/2
/3
/13
Reduced capacity (W)
400
500
800
1400