background image

Conversion Kit

6

4)

To adjust the cooktop for LP gas or to return to
Natural Gas use, refer to the tables below. 

Natural gas

Qt

Injector

Qr

BTU

Ø mm

BTU

Front Right

5200

1.10

1500

Front Left

3400

0.90

1200

Central

Inner

3000

0.85

1200

Outer

12000

1.17-1.17

4500

Rear Right

10000

1.52

2600

Rear Left

10000

1.52

2600

LP

Qt

Injector

Qr

By-pass

BTU

Ø mm

BTU

mm

Front Right

5200

0.65

(drw.0222)

1500

0.39

Front Left

3400

0.54

(drw.0222)

1200

0.33

Central

Inner

3000

0.50

(drw.0222)

1000

0.33

Outer

12000

0.70-0.70

(drw.0222)

4000

0.65

Rear Right

10000

0.90

(drw.0222)

2400

0.45

Front Left

10000

0.90

(drw.0222)

2400

0.45

NOTE:

 Save the nozzles removed from the appliance for future use.

  WARNING

FIRE HAZARD

-  Use a soapy solution to check for proper tightness.

-  Never test for gas leaks with a match or other flames.

-  Failure to follow this instruction can result in death or fire