INSTALLATION - 33
914779518/A
e
What to do if...
The appliance does not work:
• Make sure that the appliance is plugged in
and that the main switch is turned on.
The compressor starts to function too often or
functions continuously:
• The room temperature is too high.
• The door is being opened too often or for
too long.
• The door is not closing/sealing properly.
• There is an excessive quantity of non-cooled
bottles.
There is excessive condensate build-up inside
the wine cellar:
• The door is being opened too often or for
too long.
• Warm bottles have been placed inside the
wine cellar.
• The door seal is damaged or dirty. Clean or
replace it.
Water builds up inside the wine cellar:
• The drainage channel or opening is
blocked.
The wine cellar cooling is insufficient:
• The temperature set on the display is too
high.
• The door is being opened too often or for
too long.
• The door is not closing/sealing properly.
• The room temperature is too high.
INSTALLATION
Electrical connection
General information
• Check the mains characteristics against the
data indicated on the plate. The
identification plate bearing the technical
data, serial number and brand name is
visibly positioned inside the appliance. Do
not remove this plate for any reason.
• Make sure that the plug and socket are of
the same type.
• Avoid using adapters, gang sockets or
shunts as these could cause overheating
and a risk of burns.
• Leave the appliance standing for at least
two hours before turning it on for the first
time.
• If it is necessary to replace the power cable,
this must be performed by an authorised
technician from Technical Support Service.
Positioning
Choice of location
Always install the appliance in a dry place with
satisfactory ventilation. Depending on its climate
class (stated on the nameplate inside), the wine
cellar can be used in different temperature
conditions.
SN = Subnormal - N = Normal
ST = Subtropical - T = Tropical
• Locate the appliance at least 3 cm away
from electrical or gas cookers and at least
30 cm away from combustion heaters or
radiators.
• The appliance must not be installed near
heat sources. If this is not possible, suitable
insulation must be used.
• Ensure that the appliance is located with
sufficient space for the door to open and for
the internal drawers and shelves to be
removed, if necessary.
• To ensure correct cooling of the condenser,
respect the clearance requirements when
mounting.
Levelling
To level the appliance correctly, there are four
See General safety instructions.
Class
Room temperature
SN
+ 10°C to + 32°C
N
+ 16°C to + 32°C
ST
+ 16°C to + 38°C
T
+ 16°C to + 43°C
SN-ST
+ 10°C to + 38°C
SN-T
+ 10°C to + 43°C
Class
Room temperature