![SME AC-M1 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/sme/ac-m1/ac-m1_manual_1301290046.webp)
with serial communication software .
2. If this alarm remains after 2 or more default restoring, replace the control board .
CRC fault alarm
●
Alarm code
: 83
●
Alarm level
: 1
●
Alarm cause
: Faulty EEPROM or mismatching software release.
In case of such alarm, follow this procedure:
1. Restore EEPROM with EyePlus application software, using the “RESTORE” item
present in the EyePlus main page;
2. If the alarm is still present, replace the AC-M1.
Bank CRC restored
●
Alarm code
: 84
●
Alarm level
: 7
●
Alarm cause
: there was an EEPROM restore, caused by a CRC alarm.
In case of such alarm, switch on the system and then turn it on again
PRELIMINARY VERSION
46
Содержание AC-M1
Страница 1: ...AC M1 AC M1 PRELIMINARY VERSION...
Страница 9: ...Figure 1 AC M1 All the dimensions are in millimetres PRELIMINARY VERSION 9...
Страница 13: ...Figure 2 Planarity specifications for the AC M1with aluminium baseplate PRELIMINARY VERSION 13...
Страница 21: ...Figure 3 General electrical vehicle PRELIMINARY VERSION 21...
Страница 22: ...Figure 4 Connection scheme of AC M1 controlling a pump motor in a twin drive system PRELIMINARY VERSION 22...
Страница 32: ...Figure 5 Interconnection cable PRELIMINARY VERSION 32...
Страница 36: ...Figure 9 Drawing of COMPACT display slot PRELIMINARY VERSION 36...
Страница 55: ...PRELIMINARY VERSION 55 Figure 13...