Z/ISE3-TFK26GB-A
Error Display
Error Nature
Troubleshooting Method
The set data has been
changed by some
means.
Press the RESET button
and set all data again.
Load of OUT1 has short-
circuited and overcurrent
has occurred.
Turn off the power
supply and replace the
load connected to the
OUT1 (black wire).
Load of OUT2 has short-
circuited and overcurrent
has occurred.
Turn off the power
supply and replace the
load connected to the
OUT2 (white wire).
Pressure exceeding 0.5
MPa has been applied
(In case of positive
pressure, pressure
exceeding the rated
pressure has been
applied.)
Lower the pressure to
0.5 MPa or less. (In case
of positive pressure,
lower the pressure to the
rated pressure or less.)
Compared with the
ambient pressure, 0.07
MPa (in case of 1 MPa
use) or 7 kPa or more
(in case of vacuum use
or 100 kPa use) has
been applied during 0
clear.
After adjusting the
pressure to the ambient
pressure, perform
RESET operation.
When an error occurs, take actions as follows.
Output Specification
-21
Switch Output
NPN open collector output
2 outputs
Max. 30 V, 80 mA
-22
Switch Output
NPN open collector output
2 outputs
Max. 30 V, 80 mA
Analogue output 1 to 5V
(±5%F.S.)
Output impedance: Approx. 1 k
Ω
-23
Switch Output
NPN open collector output
1 output
Max. 30 V, 80 mA
Failure predictive output
NPN open collector output
1 output
-24
Switch Output
NPN open collector output
1 output
Max. 30 V, 80 mA
Failure predictive output
NPN open collector output
1 output
Analogue Output (±5 %F.S)
1 to 5V (±5 %F.S.)
Output impedance: Approx. 1 k
Ω
LED Green
LED Red
M
a
in
c
ir
c
u
it
+
-
DC
12 to 24V
Load
Load
Tr1 D1
Tr2
D2
Brown [+]
Black [1]
White [2]
Blue [-]
OUT1
OUT2
LED Green
LED Red
M
a
in
c
ir
c
u
it
+
-
DC
12 to 24V
Load
Load
Tr1 D1
Tr2
D2
Brown
Black
White
Blue
Grey
Analogue output
OUT1
OUT2
LED Green
LED Red
M
a
in
c
ir
c
u
it
+
-
DC
12 to 24V
Load
Load
Tr1 D1
Tr2
D2
OUT1
Failure predictive output
Brown [+]
Black [1]
White [2]
Blue [-]
LED Green
LED Red
M
a
in
c
ir
c
u
it
+
-
DC
12 to 24V
Load
Load
Tr1 D1
Tr2
D2
Brown
Black
White
Blue
Gray
Analogue output
OUT1
Failure predictive output
Connector Connecting
• When connecting a connector, insert the connector straight by tightly
holding its lever and body and lock it, making sure the lever hook is
securely locked into the groove of the housing.
Connector Disconnecting
• When disconnecting the connector, pull it straight away from the hous-
ing by pressing the lever and removing the lever hook from the groove.
Connector
Lever
Pins
Slot
9. Internal Circuit and Wiring
Replacement of Filter Elements
If filter element clogging causes deterioration of the absorption force or
slows the response time, stop operation and replace the filter element.
Filter Element product number : ZX1-FE
Confirm that the filter gasket is seated in the groove before reassembling
the parts.
Filter Case
•
The case is made of polycarbonate. Therefore, do not use it in an
environment that is exposed to chemicals such as thinner, carbon
tetrachloride, chloroform, acetic ester, aniline, cyclohexane,
trichloroethylene, sulfuric acid, lactic acid, or water-soluble cutting
oil (alkalinic).
Filter case
Filter element (ZX1-FE)
Filter gasket
Gasket groove
10. Maintenance
Connector Wiring
Crimping of Lead Wire and Socket
Strip 3.2 to 3.7 mm from the tip of the lead wire and fit a crimp using
the recommended crimping tool. Then insert the core wires carefully
into a socket.
Ensure that the cover of the lead wire does not enter the wire crimp-
ing area (Crimping tool: model no. DXT170-75-1).
Attachment of Socket with Lead Wire
Insert a socket into the square hole in the connector (+, 1, 2, – indi-
cation provided).
Holding by the lead wire, push it all the way in until the hook on the
socket catches and locks in the seat of the connector. (When the lead
wire is pushed in, the hook opens and locks it automatically.) Then
pull the lead wire gently to confirm that it is locked.
Removal of Socket with Lead Wire
To remove a socket from the connector, pull the lead wire out while
pressing in the socket’s hook using a bar with a thin end (approxi-
mately 1 mm). If the socket is to be re-used, open the hook outward.
Lead wire
0.2 to 0.33mm
2
Max. sheathed dia.
ø
1.7mm
Socket
Model DXT170-71-1
Pin assignment
Hook
Housing
Connector
Lever
Pins
Slot
11. Error Indication
AUSTRIA
(43) 2262 62280
NETHERLANDS
(31) 20 531 8888
BELGIUM
(32) 3 355 1464
NORWAY
(47) 67 12 90 20
CZECH REP.
(420) 541 424 611
POLAND
(48) 22 211 9600
DENMARK
(45) 7025 2900
PORTUGAL
(351) 21 471 1880
FINLAND
(358) 207 513513
SLOVAKIA
(421) 2 444 56725
FRANCE
(33) 1 6476 1000
SLOVENIA
(386) 73 885 412
GERMANY
(49) 6103 4020
SPAIN
(34) 945 184 100
GREECE
(30) 210 271 7265
SWEDEN
(46) 8 603 1200
HUNGARY
(36) 23 511 390
SWITZERLAND
(41) 52 396 3131
IRELAND
(353) 1 403 9000
UNITED KINGDOM
(44) 1908 563888
ITALY
(39) 02 92711
URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)
Specifications are subject to change without prior notice from the manufacturer.
The descriptions of products in this document may be used by other companies.
© SMC Corporation All Rights Reserved.
Contact