Doc. No. ZQ-OM01301-A
- 30 -
9. Specifications
9.1
Product specifications
Item
ZQ
□
A
series
Operating temperature range [
o
C]
5 to 50 (No condensation)
Fluid
Air
Vibration resistance [m/s
2
]
Note1)
20
Impact resistance [m/s
2
]
Note 2)
100
Standards
CE marking, RoHS
Note 1) 10 to 150 Hz., 2 hours in the directions of X, Y, and Z respectively (not energized, initial value)
Note 2) 3 times in the directions of X, Y, and Z respectively (not energized, initial value)
General Specifications
Item
ZQ05
□
A
ZQ07
□
A
ZQ10
□
A
Nozzle diameter [mm]
0.5
0.7
1.0
Standard supply pressure [MPa]
0.35
0.43
Max. vacuum pressure [kPa]
Note 1)
-80
Max.suction
flow[L/min (ANR) ]
Note 1)
5
10
22
Air consumption [L/min (ANR) ]
Note 1)
15
25
47
Supply
pressure
range
[MPa]
Vacuum
pressure supply (PV) port
0.3 to 0.5
Release pressure supply port (PD port)
Note 2)
0 to 0.5
Maximum supply
pressure [MPa]
0.75
Number of Manifold Stations that Can Operate
Simultaneously
8
6
4
Noise Level
[dB (A) ]
Note 3)
Single unit
65
68
70
Manifold
(
Maximum number of Stations that
can be connected simultaneously
)
64
66
68
Note 1) Values are based on SMC measurement standards. They depend on atmospheric pressure (weather, altitude) and measurement
method.
Note 2) The pressure must be the P port pressure or less.
Note 3) Actual values under SMC’s measurement conditions (Not guaranteed values)
Vacuum ejector system specifications
Item
ZQ000A
Flow characteristics V
→
PV
(vacuum side)
C[dm
3
/ (s
・
bar) ]
0.31
B
0.23
Cv
0.09
Flow characteristics PD
→
V
(release side)
Note 1)
C[dm
3
/ (s
・
bar) ]
0.24
B
0.26
Cv
0.08
Operating pressure range [MPa]
Note 2)
Vacuum pressure
supply (PV) port [kPa]
0 to -101.3
Pilot pressure supply (PS)
port [MPa]
0.3 to 0.5
Release pressure supply
port (PD port) [MPa]
0
to 0.5
Note 1) When the vacuum release flow adjusting needle is fully open.
Note 2) The pressure must be the P port pressure or less.
Vacuum pump system specification