![SMC Networks ZK2 Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/smc-networks/zk2-series/zk2-series_operation-manual_1301055034.webp)
-33-
No. ZK2-OM00201
(11) Filter element
(10 pcs. per set)
ZK2 - FE1 - 3 - A
(12) Check valve
Note)
(10 pcs. per set)
ZK2 - CV - A
Note) When mounting a check valve additionally, the workpiece may not be removed unless vacuum release pressure is applied.
(13) Pressure switch for vacuum assembly
ZK2-ZS E A M G
G
- A
[1]
[2]
[3]
[4]
[5]
[1] Rated pressure range and function
E
0 to -101 kPa
Pressure switch for vacuum
Open collector 2 outputs
F
-100 to 100 kPa
V
-100 to 100 kPa
Pressure switch with energy saving function
Open collector 1 output
[2] Output specifications
A
NPN
B
PNP
[3] Unit specifications
Nil
Unit selection function
Note 1)
M
SI unit only
Note 2)
Note 1) Unit selection function is not available in Japan due to new measurement law.
Note 2) Fixed unit: kPa
[4] Lead wire with connector
Nil
None
G
When 1. Is “E” or “F”: Lead wire with connector (Length 2m)
for pressure switch for vacuum
When 1. Is “V”: Lead wire with connector (Length 2m)
for pressure switch with energy saving function
[5] Mounting
Note)
Nil
Mounted to the single unit
L
Mounted to the manifold
Note) The screw length mounted to the ejector is different.
When ordering an ejector without valve, select Nil for mounting.
Nominal filtration rating
3
30
μm