SMC Networks ZFB Series Скачать руководство пользователя страница 5

 

-4-

ZFB Series 

  Specific Product Precautions 

Be sure to read this before handling the products. 

Refer to “Handling Precautions for SMC Products” (M-E03-3) for Safety Instructions

 

 

Design

 

 
 

 
1. 

Confirm the specifications.

 

Products represented in this catalog are 

designed only for use in compressed air 
systems (including vacuum). 

Do not operate at pressures, temperatures, 
etc., beyond the

 

range of specifications, as 

this can cause damage or malfunction. (Refer 
to the specifications.) 

Please contact SMC when using a fluid other 
than compressed air (including vacuum). 

2. The product may be damaged if used in the 

line with continuous pressurisation. 

3. Modification prohibited 

Do not make any modifications, including 
additional machining. 

It may cause human injury and/or an accident 
and will void the warranty. 

 

Mounting

 

 
 
 

1. Maintenance space 

Allow sufficient space for maintenance and 
inspection. 

2. Connect tubing to the IN and OUT 

One-touch fittings in accordance with the 
precautions for Onetouch fittings. 

 
 
 

1. Connect the piping to the correct ports, IN 

and  OUT.

 

This  product  cannot  be  used 

when the connection is reversed. 

2. Allow a sufficient margin of tube length 

when piping in order to prevent twisting, 
tensile, moment loads, vibration, or impact 
being applied to the tubes and filter body. 

 

Air Supply

 

 
 
 

1. Use clean air. 

Do not use compressed air that contains 
chemicals, synthetic oils that include organic 
solvents, salt, corrosive gases, etc., as they 
can cause damage or malfunction.

 

 

 

 

Operating Environment

 

 
 
 

1. Do not use in an atmosphere where 

corrosive gases, chemicals, sea water, 
water, or water steam is present. Do not 
use in cases where there is direct contact 
with any of the above. 

2. Do not use in a place subject to heavy 

vibration and/or impact. 

3. Do not use in an environment where 

flammable gas or explosive gas is present. 
Usage may cause a fire or explosion. The 
products do not have an explosion proof 
construction. 

4. The valve should not be exposed to 

prolonged sunlight. 

Use a protective cover if necessary. 

5. Remove any sources of excessive heat. 
6. In locations where there is contact with 

water, oil, weld spatter, etc., take suitable 
protective measures. 

 

Maintenance 

 
 
 

1. Maintenance work 

If handled improperly, compressed air can be 
dangerous. 
The assembly, handling, repair, and element 
replacement of pneumatic systems should be 
performed by a knowledgeable and 
experienced person. 

2. Removal of equipment and supply/exhaust 

of compressed air 

When components are removed, first confirm 
that measures are in place to prevent 
workpieces from dropping, run-away 
equipment, etc. Then, cut off the supply 
pressure and electric power, and exhaust all 
compressed air from the system using the 
residual pressure release function. 

When the equipment is operated after 
remounting or replacement, confirm that the 
equipment is operating normally. 

 

 

Warning

 

Warning

 

Caution

 

Warning

 

Warning

 

Warning

 

Содержание ZFB Series

Страница 1: ...Doc No ZF OMW0008 PRODUCT NAME Air Suction Filter With One touch Fittings MODEL Series Product Number ZFB Series ZFB10 ZFB20 ZFB30 ZFB401 03 ...

Страница 2: ... 1 Contents Page Safety Instructions 2 to 3 ZFB Series Specific Product Precautions 4 1 Product components and functions 5 2 Specifications 6 to 7 3 Mounting 8 4 Element Replacement 8 to 9 ...

Страница 3: ...possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or a...

Страница 4: ...rred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product due to the u...

Страница 5: ...at contains chemicals synthetic oils that include organic solvents salt corrosive gases etc as they can cause damage or malfunction Operating Environment 1 Do not use in an atmosphere where corrosive gases chemicals sea water water or water steam is present Do not use in cases where there is direct contact with any of the above 2 Do not use in a place subject to heavy vibration and or impact 3 Do ...

Страница 6: ...clogged stop operation and adjust the internal pressure of the filter to atmospheric pressure before replacing the element 1 When the element comes to the end of its life immediately replace it with a new filter or replacement element 2 Timing of element replacement The replacement time for elements is when one of the following conditions occurs 1 After 1 year of usage has elapsed 2 When the press...

Страница 7: ...Note Body PBT Main body Clear cover Transparent special nylon Plug Brass Electroless nickel plating Element PVF Catches foreign matter Replace the element when it is clogged O ring NBR Seals the body Universal joint PBT IN side tube can be mounted Unrestricted 360o piping tube mounting on the IN side ...

Страница 8: ...1584 30 1980 40 3016 Metric size Release button Light gray Inch size Release button Orange Applicable tubing size Metric size ZFB10 ZFB20 ZFB30 04 φ4 06 φ6 08 φ8 10 φ10 Symbol Applicable tubing Applicable model Inch size ZFB10 ZFB20 ZFB30 ZFFB40 05 φ3 16 07 φ1 4 11 φ3 8 13 φ1 2 Symbol Applicable tubing Applicable model ...

Страница 9: ...kPa Applicable tubing material Nylon Soft Nylon Polyurethane Note Alcohol acetone etc also cause damage so be sure for the product not to be close to them 2 3 Dimensions Size Model A B C D E F G H I J K L M N ZFB100 04 53 4 ZFB100 06 54 6 ZFB200 06 6 ZFB200 08 8 ZFB300 08 69 5 8 ZFB300 10 70 10 ZFB101 05 53 24 17 5 3 16 ZFB101 07 54 24 2 17 7 1 4 ZFB201 07 52 28 65 24 5 13 5 27 2 19 7 16 61 17 5 1...

Страница 10: ...n Flush the piping line before the starting actual operation when the filter is used for the first time or has been replaced 4 Element Replacement The replacement time for elements is when one of the following conditions occurs 1 After 1 year of usage has elapsed 2 When the pressure drop reaches 20 kPa even though the operating period has been less than 1 year Replacement Element Part No Part No A...

Страница 11: ...ake out the element Eliminate any dust in the transparent cover by blowing air Make sure there is no damage of the O ring 4 Insert a new element into the body 5 Set the arrowhead on the collar of the transparent cover to the protruding portion on the O side push the transparent cover into the body and set the arrowhead from the protruding portion on the O side to the protruding portion on the L si...

Страница 12: ...da ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2018 SMC Corporation All Rights Reserved ...