background image

 

-2-

 

Air Suction Filter With One-touch Fittings 

       

Safety Instructions 

 
 
These safety instructions are intended to prevent hazardous situations and/or equipment damage. 
These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They  are  all  important  notes  for  safety  and  must  be  followed  in  addition  to  International  Standards 
(ISO/IEC)

1)

 , and other safety regulations. 

1) ISO 4414: Pneumatic fluid power -- General rules relating to systems. 

 

  ISO 4413: Hydraulic fluid power -- General rules relating to systems. 

 

  IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements) 

 

  ISO 10218: Manipulating industrial robots -Safety.

                                                                                 

 

 

  etc. 

   

 

 
 

Caution 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning 

Warning 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger 

Danger 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning 

1. The compatibility of the product is the responsibility of the person who designs the equipment or 

decides its specifications. 
Since  the  product  specified  here  is  used  under  various  operating  conditions,  its  compatibility  with  specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This  person  should  also  continuously  review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment. 

2. Only personnel with appropriate training should operate machinery and equipment. 

The product specified here may become unsafe if handled incorrectly. 
The  assembly,  operation  and  maintenance  of  machines  or  equipment  including  our  products  must  be 
performed by an operator who is appropriately trained and experienced. 

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed. 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 
    and the power from any appropriate source is cut, and read and understand the specific product precautions 
    of all relevant products carefully. 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 

4. Contact SMC beforehand and take special consideration of safety measures if the product is to 

be used in any of the following conditions. 
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
    direct sunlight. 
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog. 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis. 

4.Use  in  an  interlock  circuit,  which  requires  the  provision  of  double  interlock  for  possible  failure  by  using  a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

 

Содержание ZFB Series

Страница 1: ...Doc No ZF OMW0008 PRODUCT NAME Air Suction Filter With One touch Fittings MODEL Series Product Number ZFB Series ZFB10 ZFB20 ZFB30 ZFB401 03 ...

Страница 2: ... 1 Contents Page Safety Instructions 2 to 3 ZFB Series Specific Product Precautions 4 1 Product components and functions 5 2 Specifications 6 to 7 3 Mounting 8 4 Element Replacement 8 to 9 ...

Страница 3: ...possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or a...

Страница 4: ...rred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product due to the u...

Страница 5: ...at contains chemicals synthetic oils that include organic solvents salt corrosive gases etc as they can cause damage or malfunction Operating Environment 1 Do not use in an atmosphere where corrosive gases chemicals sea water water or water steam is present Do not use in cases where there is direct contact with any of the above 2 Do not use in a place subject to heavy vibration and or impact 3 Do ...

Страница 6: ...clogged stop operation and adjust the internal pressure of the filter to atmospheric pressure before replacing the element 1 When the element comes to the end of its life immediately replace it with a new filter or replacement element 2 Timing of element replacement The replacement time for elements is when one of the following conditions occurs 1 After 1 year of usage has elapsed 2 When the press...

Страница 7: ...Note Body PBT Main body Clear cover Transparent special nylon Plug Brass Electroless nickel plating Element PVF Catches foreign matter Replace the element when it is clogged O ring NBR Seals the body Universal joint PBT IN side tube can be mounted Unrestricted 360o piping tube mounting on the IN side ...

Страница 8: ...1584 30 1980 40 3016 Metric size Release button Light gray Inch size Release button Orange Applicable tubing size Metric size ZFB10 ZFB20 ZFB30 04 φ4 06 φ6 08 φ8 10 φ10 Symbol Applicable tubing Applicable model Inch size ZFB10 ZFB20 ZFB30 ZFFB40 05 φ3 16 07 φ1 4 11 φ3 8 13 φ1 2 Symbol Applicable tubing Applicable model ...

Страница 9: ...kPa Applicable tubing material Nylon Soft Nylon Polyurethane Note Alcohol acetone etc also cause damage so be sure for the product not to be close to them 2 3 Dimensions Size Model A B C D E F G H I J K L M N ZFB100 04 53 4 ZFB100 06 54 6 ZFB200 06 6 ZFB200 08 8 ZFB300 08 69 5 8 ZFB300 10 70 10 ZFB101 05 53 24 17 5 3 16 ZFB101 07 54 24 2 17 7 1 4 ZFB201 07 52 28 65 24 5 13 5 27 2 19 7 16 61 17 5 1...

Страница 10: ...n Flush the piping line before the starting actual operation when the filter is used for the first time or has been replaced 4 Element Replacement The replacement time for elements is when one of the following conditions occurs 1 After 1 year of usage has elapsed 2 When the pressure drop reaches 20 kPa even though the operating period has been less than 1 year Replacement Element Part No Part No A...

Страница 11: ...ake out the element Eliminate any dust in the transparent cover by blowing air Make sure there is no damage of the O ring 4 Insert a new element into the body 5 Set the arrowhead on the collar of the transparent cover to the protruding portion on the O side push the transparent cover into the body and set the arrowhead from the protruding portion on the O side to the protruding portion on the L si...

Страница 12: ...da ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2018 SMC Corporation All Rights Reserved ...

Отзывы: