VG300**-OMH0006-A 

 

 

Air Supply 

 
 

1. If ultra dry air is used as a fluid, the lubrication 

characteristics of the equipment will 
deteriorate and this can affect the reliability 
(life) of the product. Contact SMC beforehand, 
if using ultra dry air. 

2. Install an air filter. 

Install an air filter upstream near the valve. 

Select an air filter with a filtration size of 5

µ

m or smaller. 

3. Install an aftercooler, air dryer or drain catch 

before the filter and take appropriate 
measures. 

Compressed air that contains a large amount of 

drainage can cause malfunction of pneumatic equipment 

such as valves. Take measures to ensure air quality, 

such as installing an aftercooler, air dryer, or water 

separator. 

4. If excessive carbon powder is generated, 

eliminate it by installing mist separators on the 
upstream side of valves. 

If excessive carbon dust is generated by the compressor, 

it may adhere to the inside of a valve and cause it to 

malfunction. 

 

For detailed information regarding the quality of the 

compressed air described above, refer to SMC's "Air 

Cleaning Systems". 

 

Environment 

 
 

1) Do not use in an environment where corrosive 

gases, chemicals, sea water, water or steam are 

present. 

2) Do not use in an environment where flammable gas 

or explosive gas exists. Usage may cause a fire or an 

explosion. The product do not have an explosion 

proof construction. 

3) Do not use in a place subject to heavy vibration 

and/or shock. 

4) The valve should not be exposed to prolonged 

sunlight. Use a protective cover. 

5) Remove any sources of excessive heat. 

6) If it is used in an environment where there is 

possible contact with oil, weld spatter, etc., exercise 

preventive measures. 

 
 
 

 

Maintenance and Inspection

 

 

 

(1) Maintenance should be performed according 

to the procedure indicated in the Operation 
Manual (this copy). 

Improper handling can cause an injury; damage and/or 

malfunction of equipment and machinery. 

(2) Removal of equipment, and supply/exhaust of 

compressed air 

When components are removed, first confirm that 

measures are in place to prevent workpieces from 

dropping, run-away equipment, etc. Then, cut off the 

supply pressure and electric power, and exhaust all 

compressed air from the system using its residual 

pressure release function. 

When the equipment is operated after remounting or 

replacement, first confirm that measures are in place to 

prevent lurching of actuators, etc. Then, confirm that the 

equipment is operating normally. 

(3) Low frequency operation 

Valve should be operated at least once every 30 days to 

prevent malfunction. (Use caution regarding the air 

supply.) 

 

    

1. Draining 

Remove drainage from air filters regularly. 

2. Lubrication 

Lubrication must be continued once it has been used in 

the system. 

Use class 1 turbine oil (with no additive), ISO 
VG32.

 

If other lubricant oil is used, it may cause malfunction. 

Please contact SMC for suggested class 2 turbine oil 

(with additives), ISO VG32. 

    

 

 
 
 

    

 

 

 

Caution 

Warning 

Warning 

Caution 

VGA342R  Series 

3-port  air  operated  valve  /  Precautions  (3) 

 

Make sure to read this before handling. 

Содержание VGA342R Series

Страница 1: ...Doc No VG300 OMH0006 A PRODUCT NAME Air operated valve MODEL Series Product Number VGA342R Series...

Страница 2: ...ts Safety Instructions 2 3 Design Selection 4 Installation 4 Wiring 5 Lubrication 5 Air source 5 6 Operating Environment 6 Maintenance and Inspection 6 Specific Product Precautions 7 Trouble shooting...

Страница 3: ...n who has determined its compatibility with the product This person should also continuously review all specifications of the product referring to its latest catalog information with a view to giving...

Страница 4: ...d warranty and Disclaimer the product is 1 year in service or 1 5 years after the product is Also the product may have specified durability running distance or replacement parts Please consult your ne...

Страница 5: ...system having a vacuum the vacuum condition will not be maintained Use a valve designed for use under vacuum condition 8 Ventilation When using the valve in a closed control panel etc install ventilat...

Страница 6: ...ithin the system since the original lubricant applied within the product during manufacturing will be washed away please continue to supply lubrication to the system Without continued lubrication malf...

Страница 7: ...r shock 4 The valve should not be exposed to prolonged sunlight Use a protective cover 5 Remove any sources of excessive heat 6 If it is used in an environment where there is possible contact with oil...

Страница 8: ...to the value the same as the operating pressure Handling precautions 1 As the PE port is the exhaust port of the pilot valve do not plug or restrict it 2 The X port is the pressure supply port of the...

Страница 9: ...actuators such as cylinder 7 Sealing failure O ring is worn 6 Lodging of foreign matter For body ported type and N O specification from 1 P port Perform troubleshooting with higher possibilitybased o...

Страница 10: ...ely mount an auto drain or install a dryer and replace the valve 6 If air leakage is caused by foreign matter remove foreign matter in the piping by air blow and replace the valve 7 Repair or replace...

Страница 11: ...1993 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation...

Отзывы: